A prospective multicenter trial testing the SCOTI device for confirmation of endotracheal tube placement

被引:6
作者
Li, J [1 ]
机构
[1] Harvard Univ, Sch Med, Mt Auburn Hosp, Div Emergency Med, Cambridge, MA 02238 USA
关键词
airway; intubation; esophageal; tracheal; SCOTI; detector; prospective;
D O I
10.1016/S0736-4679(00)00317-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We sought to characterize the Sonomatic Confirmation of Tracheal Intubation (SCOTI) device's ability to confirm endotracheal tube location during realtime intubation in emergency and elective settings. Data were prospectively collected during a multicenter convenience-sample observational trial of emergency and elective intubation cases. In addition to tracheal and inadvertent esophageal intubations in emergency patients, intentional esophageal intubations were also performed to improve specificity calculations in consenting elective surgical patients. Data analysis included descriptive statistics as well as calculations of sensitivity, specificity, and 95% confidence intervals (CI), Data were obtained from 220 tracheal and 103 esophageal intubations, 137 (42%) performed in emergency patients. Fifteen tracheal intubations were incorrectly identified by SCOTI as esophageal and two esophageal intubations incorrectly as tracheal, Sensitivity and specificity were thus 93% (CI 90-97%) and 98% (CI94-99%), respectively. The two false-positive cases were attributed to gaseous distension of the stomach and esophagus from prolonged bag-valve-mask ventilation. In addition to use in postprocedure tube placement confirmation, SCOTI aided the intubation procedure itself in 45 difficult emergency attempts (33%), 26 of which necessitated blind tube passage. We conclude that the SCOTI device has high sensitivity and specificity for tube placement confirmation during tracheal intubation attempts in both emergency and elective settings, It also facilitates tube placement itself during difficult intubations. As such it may be considered an adjunctive device to minimize the potentially fatal complication of esophageal intubation. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:231 / 239
页数:9
相关论文
共 17 条
[1]  
[Anonymous], ANESTHESIOL NEWS JAN
[2]   VALIDITY OF A DISPOSABLE END-TIDAL CO2 DETECTOR IN VERIFYING ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS AND CHILDREN [J].
BHENDE, MS ;
THOMPSON, AE ;
COOK, DR ;
SAVILLE, AL .
ANNALS OF EMERGENCY MEDICINE, 1992, 21 (02) :142-145
[3]   Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation [J].
Bozeman, WP ;
Hexter, D ;
Liang, HK ;
Kelen, GD .
ANNALS OF EMERGENCY MEDICINE, 1996, 27 (05) :595-599
[4]   An evaluation of the SCOTI device [J].
Haridas, RP ;
Chesshire, NJ ;
Rocke, DA .
ANAESTHESIA, 1997, 52 (05) :453-456
[5]   COLORIMETRIC END-TIDAL CO2 DETECTOR FOR VERIFICATION OF ENDOTRACHEAL-TUBE PLACEMENT IN OUT-OF-HOSPITAL CARDIAC-ARREST [J].
HAYDEN, SR ;
SCIAMMARELLA, J ;
VICCELLIO, P ;
THODE, H ;
DELAGI, R .
ACADEMIC EMERGENCY MEDICINE, 1995, 2 (06) :499-502
[6]   AIRWAY GEOMETRY BY ANALYSIS OF ACOUSTIC PULSE RESPONSE MEASUREMENTS [J].
JACKSON, AC ;
BUTLER, JP ;
MILLET, EJ ;
HOPPIN, FG ;
DAWSON, SV .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (03) :523-536
[7]   THE SYRINGE ASPIRATION TECHNIQUE TO VERIFY ENDOTRACHEAL-TUBE POSITION [J].
JENKINS, WA ;
VERDILE, VP ;
PARIS, PM .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1994, 12 (04) :413-416
[8]   Safety evaluation and confidence intervals when the number of observed events is small or zero [J].
Jovanovic, BD ;
Zalenski, RJ .
ANNALS OF EMERGENCY MEDICINE, 1997, 30 (03) :301-306
[9]   Complications of emergency intubation with and without paralysis [J].
Li, J ;
Murphy-Lavoie, H ;
Bugas, C ;
Martinez, J ;
Preston, C .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1999, 17 (02) :141-143
[10]   SCOTI vs. Wee - An assessment of two oesophageal intubation detection devices [J].
Lockey, DJ ;
Woodward, W .
ANAESTHESIA, 1997, 52 (03) :242-243