Optimal elective management of patent ductus arteriosus in the older child

被引:9
作者
Forbes, TL
Evans, MG
机构
[1] CHILDRENS HOSP WESTERN ONTARIO,DIV PAEDIAT SURG,LONDON,ON N6C 2V5,CANADA
[2] UNIV WESTERN ONTARIO,DIV PEDIAT SURG,LONDON,ON,CANADA
关键词
patent ductus arteriosus; surgical ligation;
D O I
10.1016/S0022-3468(96)90127-X
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Open surgical ligation has proven to be a safe and effective method to bring about closure of the patent ductus arteriosus (PDA). Recent studies have suggested that percutaneous transcatheter and video-assisted thorascopic closure may be better and more cost-effective techniques for PDA closure. The authors reviewed their experience with open thoracotomy for the elective ligation of PDA in 42 children over a 3-year period. The male:female ratio was 1.6:1; the age of the patients (mean +/- SD) was 2.8 +/- 2.3 years and their weight was 14 +/- 7 kg. In all cases the diagnosis was confirmed preoperatively by echocardiography. Open ligation of the PDA was performed through a limited left posterolateral thoracotomy with exposure, by an extrapleural approach. Closure was established with two silk ligatures or a silk ligature and clip, and drainage of the extrapleural space was not used. The operating time was 85 +/- 12 minutes. The total duration of hospitalization was 3.1 +/- 0.8 days. There were no deaths. Successful closure was confirmed by auscultation in 39 children and by subsequent echocardiography in three patients, No surgical complications occurred, and no transfusions were required. Minor respiratory symptoms occurred in two patients postoperatively, Transient systemic hypertension was seen in two patients, and one wound infection occurred. Copyright (C) 1996 by W.B. Saunders Company
引用
收藏
页码:765 / 767
页数:3
相关论文
共 11 条
[1]   THORACOSCOPIC CLIPPING AND LIGATION OF A PATENT DUCTUS-ARTERIOSUS [J].
ALVAREZTOSTADO, RA ;
MILLAN, MA ;
TOVAR, LA ;
SHUCHLEIB, S ;
ALVAREZTOSTADO, R ;
CHOUSLEB, A .
ANNALS OF THORACIC SURGERY, 1994, 57 (03) :755-757
[2]  
CAMPBELL M, 1968, BRIT HEART J, V30, P4
[3]   CLINICAL OUTCOMES AND COSTS OF TRANSCATHETER AS COMPARED WITH SURGICAL CLOSURE OF PATENT DUCTUS-ARTERIOSUS [J].
GRAY, DT ;
FYLER, DC ;
WALKER, AM ;
WEINSTEIN, MC ;
CHALMERS, TC .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (21) :1517-1523
[4]   Surgical ligation of a patent ductus arteriosus - Report of first successful case [J].
Gross, RE ;
Hubbard, JP .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1939, 112 :729-731
[5]   SIMPLIFIED MUSCLE-SPARING THORACOTOMY FOR PATENT DUCTUS-ARTERIOSUS LIGATION IN NEONATES [J].
KARWANDE, SV ;
ROWLES, JR .
ANNALS OF THORACIC SURGERY, 1992, 54 (01) :164-165
[6]   A NEW VIDEO-ASSISTED THORACOSCOPIC SURGICAL TECHNIQUE FOR INTERRUPTION OF PATENT DUCTUS-ARTERIOSUS IN INFANTS AND CHILDREN [J].
LABORDE, F ;
NOIRHOMME, P ;
KARAM, J ;
BATISSE, A ;
BOUREL, P ;
SAINTMAURICE, O ;
AMATO, JJ ;
MAVROUDIS, C .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 105 (02) :278-280
[7]   CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS WITH A LIGACLIP THROUGH A MINITHORACOTOMY [J].
MAJID, AA .
CHEST, 1993, 103 (05) :1512-1514
[8]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC AND COLOR FLOW DOPPLER EVALUATION OF DUCTAL OCCLUSION WITH THE RASHKIND PROSTHESIS [J].
MUSEWE, NN ;
BENSON, LN ;
SMALLHORN, JF ;
FREEDOM, RM .
CIRCULATION, 1989, 80 (06) :1706-1710
[9]   FREQUENCY OF OCCURRENCE OF RESIDUAL DUCTAL FLOW AFTER SURGICAL LIGATION BY COLOR-FLOW MAPPING [J].
SORENSEN, KE ;
KRISTENSEN, BO ;
HANSEN, OK .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (07) :653-654
[10]   OUTPATIENT CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS [J].
WESSEL, DL ;
KEANE, JF ;
PARNESS, I ;
LOCK, JE .
CIRCULATION, 1988, 77 (05) :1068-1071