Radially expanding dilatation - A superior method of laparoscopic trocar access

被引:46
作者
Bhoyrul, S [1 ]
Mori, T [1 ]
Way, LW [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT SURG,SAN FRANCISCO,CA 94143
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 1996年 / 10卷 / 07期
关键词
laparoscopy; trocar complications; incisional hernia; radially expanding devices;
D O I
10.1007/s004649900155
中图分类号
R61 [外科手术学];
学科分类号
摘要
Trocars used in laparoscopic surgery occasionally produce serious complications, such as bleeding, visceral injury, or incisional hernia. We report the evaluation of a new, potentially safer laparoscopic access device in which the cutting obturator of a standard trocar is replaced by a blunt, radially expanding device, Conventional and radially expanding trocars were used in laparoscopic cholecystectomies in 12 pigs. Their abdominal walls were excised and the defects caused by the trocars were examined, The defects caused by the radially expanding devices were about 50% narrower (P < 0.001), and the incidence of abdominal wall bleeding was considerably less (0% vs 21%) with the radially expanding trocars, Since incisional hernias at trocar sites are related to the size of the abdominal wall defect, the use of radially expanding trocars should decrease the incidence of this complication, There should also be less risk of visceral injury.
引用
收藏
页码:775 / 778
页数:4
相关论文
共 11 条
[1]   AORTIC INJURY - A CATASTROPHIC COMPLICATION OF LAPAROSCOPIC CHOLECYSTECTOMY [J].
APELGREN, KN ;
SCHEERES, DE .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1994, 8 (06) :689-691
[2]   MAJOR VASCULAR INJURY DURING GYNECOLOGIC LAPAROSCOPY - REPORT OF A CASE AND REVIEW OF PUBLISHED CASES [J].
BAADSGAARD, SE ;
BILLE, S ;
EGEBLAD, K .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1989, 68 (03) :283-285
[3]  
HURD WW, 1993, OBSTET GYNECOL, V82, P673
[4]  
KAALI SG, 1992, J REPROD MED, V37, P617
[5]   INCISIONAL HERNIAS AFTER MAJOR LAPAROSCOPIC GYNECOLOGIC PROCEDURES [J].
KADAR, N ;
REICH, H ;
LIU, CY ;
MANKO, GF ;
GIMPELSON, R .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 168 (05) :1493-1495
[6]  
KURTZ BR, 1993, J REPROD MED, V38, P643
[7]  
Plaus W J, 1993, J Laparoendosc Surg, V3, P567, DOI 10.1089/lps.1993.3.567
[8]  
Reich H, 1992, Surg Laparosc Endosc, V2, P74
[9]   BOWEL INJURY IN OPEN TECHNIQUE LAPAROSCOPIC CANNULA PLACEMENT [J].
SADEGHINEJAD, H ;
KAVOUSSI, LR ;
PETERS, CA .
UROLOGY, 1994, 43 (04) :559-560
[10]   REDUCTION OF OPERATIONAL RISK DURING LAPAROSCOPY USING A NEW, BLUNT TROCAR [J].
TEWS, G ;
BOHAUMILITZKY, T ;
ARZT, W ;
JANACH, A ;
FROHLICH, H .
GEBURTSHILFE UND FRAUENHEILKUNDE, 1991, 51 (04) :304-306