An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics

被引:59
作者
Belov, ME [1 ]
Anderson, GA [1 ]
Wingerd, MA [1 ]
Udseth, HR [1 ]
Tang, KQ [1 ]
Prior, DC [1 ]
Swanson, KR [1 ]
Buschbach, MA [1 ]
Strittmatter, EF [1 ]
Moore, RJ [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Environm & Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1016/j.jasms.2003.09.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a fully automated high performance liquid chromatography 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer system designed for proteomics research. A synergistic suite of ion introduction and manipulation technologies were developed and integrated as a high-performance front-end to a commercial Bruker Daltonics FTICR instrument. The developments incorporated included a dual-ESI-emitter ion source; a dual-channel electrodynamic ion funnel; tandem quadrupoles for collisional cooling and focusing, ion selection, and ion accumulation, and served to significantly improve the sensitivity, dynamic range, and mass measurement accuracy of the mass spectrometer. In addition, a novel technique for accumulating ions in the ICR cell was developed that improved both resolution and mass measurement accuracy. A new calibration methodology is also described where calibrant ions are introduced and controlled via a separate channel of the dual-channel ion funnel, allowing calibrant species to be introduced to sample spectra on a real-time basis, if needed. We also report on overall instrument automation developments that facilitate high-throughput and unattended operation. These included an automated version of the previously reported very high resolution, high pressure reversed phase gradient capillary liquid chromatography (LC) system as the separations component. A commercial autosampler was integrated to facilitate 24 h/day operation. Unattended operation of the instrument revealed exceptional overall performance: Reproducibility (1-5% deviation in uncorrected elution times), repeatability (<20% deviation in detected abundances for more abundant peptides from the same aliquot analyzed a few weeks apart), and robustness (high-throughput operation for 5 months without significant downtime). When combined with modulated-ion-energy gated trapping, the dynamic calibration of FTICR mass spectra provided decreased mass measurement errors for peptide identifications in conjunction with high resolution capillary LC separations over a dynamic range of peptide peak intensities for each spectrum of 10(3) and >10(5) for peptide abundances in the overall separation. (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:212 / 232
页数:21
相关论文
共 66 条
  • [1] ABSOLUTE INTENSITIES AND PERPENDICULAR TEMPERATURES OF SUPERSONIC BEAMS OF POLYATOMIC GASES
    BEIJERINCK, HCW
    VERSTER, NF
    [J]. PHYSICA B & C, 1981, 111 (2-3): : 327 - 352
  • [2] Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
  • [3] Higher-resolution data-dependent selective external ion accumulation for capillary LC-FTICR
    Belov, ME
    Anderson, GA
    Smith, RD
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (03) : 265 - 279
  • [4] Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization
    Belov, ME
    Anderson, GA
    Angell, NH
    Shen, YF
    Tolic, N
    Udseth, HR
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5052 - 5060
  • [5] Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Auberry, KJ
    Harkewicz, R
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 38 - 48
  • [6] Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Udseth, HR
    Conrads, TP
    Veenstra, TD
    Masselon, CD
    Gorshkov, MV
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 253 - 261
  • [7] Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance
    Belov, ME
    Zhang, R
    Strittmatter, EF
    Prior, DC
    Tang, K
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (16) : 4195 - 4205
  • [8] RADIAL ION-TRANSPORT DUE TO RESISTIVE-WALL DESTABILIZATION IN FOURIER-TRANSFORM MASS-SPECTROMETRY
    BEU, SC
    LAUDE, DA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 108 (2-3): : 255 - 268
  • [9] ION TRAPPING AND MANIPULATION IN A TANDEM TIME-OF-FLIGHT-FOURIER TRANSFORM MASS-SPECTROMETER
    BEU, SC
    LAUDE, DA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 104 (02): : 109 - 127
  • [10] ODRPACK - SOFTWARE FOR WEIGHTED ORTHOGONAL DISTANCE REGRESSION
    BOGGS, PT
    DONALDSON, JR
    BYRD, RH
    SCHNABEL, RB
    [J]. ACM TRANSACTIONS ON MATHEMATICAL SOFTWARE, 1989, 15 (04): : 348 - 364