High-resolution CT using multidetector CT equipment: Evaluation of image quality in II cadaveric lungs and a phantom

被引:21
作者
Honda, O
Johkoh, T
Tomiyama, N
Kozuka, T
Mihara, N
Koyama, M
Hamada, S
Naito, H
Nakamura, H
Kudo, M
机构
[1] Osaka Univ, Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
[2] Gen Elect Yokogawa Med Syst, Hino, Tokyo 1910065, Japan
关键词
D O I
10.2214/ajr.177.4.1770875
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to evaluate the image quality and diagnostic efficacy of multidetector high-resolution CT (HRCT) by comparing it with single-detector HRCT and by comparing the noise and artifact of multidetector HRCT images with a phantom. SUBJECTS AND METHODS. Multidetector HRCT with six parameters and single-detector HRCT were performed on cadaveric lungs. The image. quality and diagnostic efficacy of multidetector HRCT were evaluated in comparison with those of single-detector HRCT. A phantom was scanned, and image artifact and noise were investigated. RESULTS. The image quality of multidetector HRCT with axial 1.25 mm x 4i (four images per gantry rotation) mode was equal to that of single-detector HRCT. The image quality of multidetector HRCT with other modes was worse than that on single-detector HRCT. The diagnostic efficacy of multidetector HRCT with high-quality mode (pitch, 3:1) and axial mode was equal to that of single-detector HRCT. The diagnostic efficacy on multidetector HRCT with high-speed mode (pitch, 6:1) was worse than that on single-detector HRCT. In the phantom study, images made in high-speed mode had strong artifacts. Noise in the axial mode was milder than that in high-speed mode but more severe than that in high-quality mode. CONCLUSION. The image quality of axial HRCT with multidetector CT is equal to that on single-detector HRCT. Axial HRCT with multidetector CT is appropriate for evaluating subtle lung abnormalities, but high-speed mode is unsuitable. Using the high-quality mode degrades image quality but is still worthwhile.
引用
收藏
页码:875 / 879
页数:5
相关论文
共 13 条
  • [1] REVIEW OF HIGH-RESOLUTION CT OF THE LUNG
    CORCORAN, HL
    RENNER, WR
    MILSTEIN, MJ
    [J]. RADIOGRAPHICS, 1992, 12 (05) : 917 - 939
  • [2] THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES
    HAAGA, JR
    MIRALDI, F
    MACINTYRE, W
    LIPUMA, JP
    BRYAN, PJ
    WIESEN, E
    [J]. RADIOLOGY, 1981, 138 (02) : 449 - 454
  • [3] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    [J]. MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [4] CHRONIC DIFFUSE INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC-ACCURACY OF HIGH-RESOLUTION AND CONVENTIONAL CT
    LEUNG, AN
    STAPLES, CA
    MULLER, NL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) : 693 - 696
  • [5] Dual-slice spiral versus single-slice spiral scanning: Comparison of the physical performance of two computed tomography scanners
    Liang, Y
    Kruger, RA
    [J]. MEDICAL PHYSICS, 1996, 23 (02) : 205 - 220
  • [6] Markarian B., 1993, LUNG RADIOLOGIC PATH, P4
  • [7] HIGH-RESOLUTION CT OF THE LUNGS - AN OPTIMAL APPROACH
    MAYO, JR
    WEBB, WR
    GOULD, R
    STEIN, MG
    BASS, I
    GAMSU, G
    GOLDBERG, HI
    [J]. RADIOLOGY, 1987, 163 (02) : 507 - 510
  • [8] THE DOUBLE-FISSURE SIGN - A MOTION ARTIFACT ON THIN-SECTION CT SCANS
    MAYO, JR
    MULLER, NL
    HENKELMAN, RM
    [J]. RADIOLOGY, 1987, 165 (02) : 580 - 581
  • [9] MAYO JR, 1991, RADIOL CLIN N AM, V29, P1043
  • [10] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2223 - 2230