Magnetic biosensors for genetic screening of cystic fibrosis

被引:24
作者
Lagae, L
Wirix-Speetjens, R
Liu, CX
Laureyn, W
Borghs, G
Harvey, S
Galvin, P
Ferreira, HA
Graham, DL
Freitas, PP
Clarke, LA
Amaral, MD
机构
[1] IMEC, MCP, B-3000 Louvain, Belgium
[2] Tyndall Natl Inst, Cork, Ireland
[3] INESC, Lisbon, Portugal
[4] Univ Lisbon, Fac Sci, Dept Chem & Biochem, P-1699 Lisbon, Portugal
来源
IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS | 2005年 / 152卷 / 04期
关键词
D O I
10.1049/ip-cds:20050022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper reports on the development of a magnetic biosensing platform for genetic analysis. The sensing technique is based on the on-chip manipulation of magnetically labelled biomolecules by the magnetic field gradient force created by current-carrying conductors; on biomolecular reactions such as the binding of complementary DNA material; and on the detection of the fringe field of the magnetic label by a magnetoresistive spin valve sensor. Different experiments will demonstrate the advantages, difficulties, prospects and potential of the combination of magnetic bead manipulation and detection on a single microchip. Early detection of DNA coding for the cystic fibrosis (CF) gene is used as a model system for proof-of-concept of the magnetic DNA biosensor platform.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 21 条
[1]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[2]   CYSTIC-FIBROSIS - MOLECULAR-BIOLOGY AND THERAPEUTIC IMPLICATIONS [J].
COLLINS, FS .
SCIENCE, 1992, 256 (5058) :774-779
[3]   The BARC biosensor applied to the detection of biological warfare agents [J].
Edelstein, RL ;
Tamanaha, CR ;
Sheehan, PE ;
Miller, MM ;
Baselt, DR ;
Whitman, LJ ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :805-813
[4]   Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited) [J].
Ferreira, HA ;
Graham, DL ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :7281-7286
[5]  
FERREIRA HA, 2005, RAPID DNA HYBRIDISAT
[6]  
FREITAS PP, 2005, MAGNETO RESISTIVE DN
[7]  
Galvin Paul, 2004, J Cyst Fibros, V3 Suppl 2, P29, DOI 10.1016/j.jcf.2004.05.006
[8]   Magnetoresistive-based biosensors and biochips [J].
Graham, DL ;
Ferreira, HA ;
Freitas, PP .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (09) :455-462
[9]   Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications [J].
Graham, DL ;
Ferreira, H ;
Bernardo, J ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) :7786-7788
[10]  
Hafeli U., 1997, Scientific and Clinical Applications of Magnetic Carriers, DOI DOI 10.1007/s10439-009-9660-y