Chip electrospray mass spectrometry for carbohydrate analysis

被引:41
作者
Zamfir, AD
Bindila, L
Lion, N
Allen, M
Girault, HH
Peter-Katalinic, J
机构
[1] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
[2] Ecole Polytech Fed Lausanne, LEPA, CH-1015 Lausanne, Switzerland
[3] Adv BioSci, Norwich, Norfolk, England
关键词
chip electrospray ionization tandem mass spectrometry; gangliosides; glycans; glycopeptides; miniaturization; protein glycosylation; review;
D O I
10.1002/elps.200500101
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Currently two types of chip systems are used in conjunction with MS: out-of-plane devices, where hundreds of nozzles, nanospray emitters are integrated onto a single silicon substrate from which electrospray is established perpendicular to the substrate, and planar microchips, embedding a microchannel at the end of which electrospray is generated in-plane, on the edge of the microchip. In the last two years, carbohydrate research greatly benefited from the introduction and implementation of the chip-based MS. In two laboratories the advantages of the chip electrospray in terms of ionization efficiency, sensitivity, reproducibility, quality of data in combination with high mass accuracy, and resolution of detection were systematically explored for several carbohydrate classes: O- and N-glycopeptides, oligosaccharides, gangliosides and glycoprotein-derived O- and N-glycans, and glycopeptides. The current state-of-the-art in interfacing the chip electrospray devices to high-performance MS for carbohydrate analysis, and the particular requirements for method optimization in both positive and negative ion modes are reviewed here. The recent applications of these miniaturized devices and their general potential for glycomic-based surveys are highlighted.
引用
收藏
页码:3650 / 3673
页数:24
相关论文
共 66 条
[1]   Sheathless reverse-polarity capillary electrophoresis-electrospray-mass spectrometry for analysis of underivatized glycoconjugates [J].
Bindila, L ;
Peter-Katalinic, J ;
Zamfir, A .
ELECTROPHORESIS, 2005, 26 (7-8) :1488-1499
[2]   A thin chip microsprayer system coupled to Fourier transform ion cyclotron resonance mass spectrometry for glycopeptide screening [J].
Bindila, L ;
Froesch, M ;
Lions, N ;
Vukelic, Z ;
Rossier, JS ;
Girault, HH ;
Peter-Katalinic, J ;
Zamfir, AD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (23) :2913-2920
[3]   Off-line capillary electrophoresis/fully automated nanoelectrospray chip quadrupole time-of-flight mass spectrometry and tandem mass spectrometry for glycoconjugate analysis [J].
Bindila, L ;
Almeida, R ;
Sterling, A ;
Allen, M ;
Peter-Katalinic, J ;
Zamfir, A .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (10) :1190-1201
[4]   Appropriate glycosylation of recombinant proteins for human use - Implications of choice of expression system [J].
Brooks, SA .
MOLECULAR BIOTECHNOLOGY, 2004, 28 (03) :241-255
[5]  
Chester MA, 1998, EUR J BIOCHEM, V257, P293
[6]  
COSTELLO CE, 1994, PROG BRAIN RES, V101, P45
[7]   Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip [J].
Dahlin, AP ;
Wetterhall, M ;
Liljegren, G ;
Bergström, SK ;
Andrén, P ;
Nyholm, L ;
Markides, KE ;
Bergquist, J .
ANALYST, 2005, 130 (02) :193-199
[8]   ALPHA-N-ACETYLGALACTOSAMINIDASE DEFICIENCY WITH MILD CLINICAL MANIFESTATIONS AND DIFFICULT BIOCHEMICAL-DIAGNOSIS [J].
DEJONG, J ;
VANDENBERG, C ;
WIJBURG, H ;
WILLEMSEN, R ;
VANDIGGELEN, O ;
SCHINDLER, D ;
HOEVENAARS, F ;
WEVERS, R .
JOURNAL OF PEDIATRICS, 1994, 125 (03) :385-391
[9]   Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine [J].
Deng, YZ ;
Henion, J ;
Li, JJ ;
Thibault, P ;
Wang, C ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :639-646
[10]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811