Sonographically guided directional vacuum-assisted breast biopsy: Preliminary experience in Venezuela

被引:45
作者
Perez-Fuentes, JA
Longobardi, IR
Acosta, VF
Marin, CE
Liberman, L
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, Breast Imaging Sect, New York, NY 10021 USA
[2] Ceclines, Caracas, Venezuela
关键词
D O I
10.2214/ajr.177.6.1771459
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the use of sonographically guided directional vacuum-assisted biopsy in the histologic diagnosis of breast lesions. MATERIALS AND METHODS. Eighty-eight lesions in 83 women underwent sonographically guided 11-gauge directional vacuum-assisted breast biopsy during a 26-month period. Biopsies were performed using high-resolution sonography equipment with a 7.5-MHz transducer, obtaining a median of 17 specimens per lesion. Imaging studies, medical records, and histologic findings were reviewed. RESULTS. Median patient age was 48 years (range, 25-78 years). Median lesion size was 1.2 cm (range, 0.4-2.5 cm). Twenty-four (27.3%) of 88 lesions were palpable. The median time required to perform biopsy was 17 min (range, 10-40 nun). Complete removal of the lesion seen at sonography occurred in 78 (88.6%) of 88 lesions and was significantly more frequent in lesions measuring 1.5 cm or less than in larger lesions (68/71 = 95.8% vs 10/17 = 58.8%, p < 0.0003). A surgical procedure was spared in 79 (95.2%) of 83 women. In 36 lesions with imaging and clinical follow-up after sonographically guided biopsy with benign findings (range, 4-24 months; median, 11.3 months), we found no evidence of cancer or scarring in the breast. CONCLUSION. In our small series, sonographically guided directional vacuum-assisted biopsy was a fast and accurate method for breast diagnosis. This technique resulted in complete removal of 95.8% of lesions shown at sonography measuring 1.5 cm or less and spared a surgical procedure in 95.2% of women. Further work is necessary to refine indications, evaluate cost-effectiveness, and assess long-term outcome.
引用
收藏
页码:1459 / 1463
页数:5
相关论文
共 31 条
[1]  
[Anonymous], BREAST IM REP DAT SY
[2]   Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model [J].
Berg, WA ;
Krebs, TL ;
Campassi, C ;
Magder, LS ;
Sun, CCJ .
RADIOLOGY, 1997, 205 (01) :203-208
[3]   Atypical ductal hyperplasia: Histologic underestimation of carcinoma in tissue harvested from impalpable breast lesions using 11-gauge stereotactically guided directional vacuum-assisted biopsy [J].
Brem, RF ;
Behrndt, VS ;
Sanow, L ;
Gatewood, OMB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1405-1407
[4]  
Burbank F, 1996, AM SURGEON, V62, P738
[5]  
Burbank F, 1997, AM SURGEON, V63, P988
[6]   Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization [J].
Burbank, F ;
Forcier, N .
RADIOLOGY, 1997, 205 (02) :407-415
[7]   Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: Results of surgical excision [J].
Darling, MLR ;
Smith, DN ;
Lester, SC ;
Kaelin, C ;
Selland, DLG ;
Denison, CM ;
DiPiro, PJ ;
Rose, DI ;
Rhei, E ;
Meyer, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) :1341-1346
[8]   Incidental treatment of nipple discharge caused by benign intraductal papilloma through diagnostic mammotome biopsy [J].
Dennis, MA ;
Parker, S ;
Kaske, TI ;
Stavros, AT ;
Camp, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1263-1268
[9]   Nondiagnostic stereotaxic core breast biopsy: Results of rebiopsy [J].
Dershaw, DD ;
Morris, EA ;
Liberman, L ;
Abramson, AF .
RADIOLOGY, 1996, 198 (02) :323-325
[10]  
DUCHESNE N, 2001, AJR S, V176, P7