Aortoiliac aneurysms: Endoluminal repair - Clinical evidence for a fully supported stent-graft

被引:21
作者
Silberzweig, JE
Marin, ML
Hollier, LH
Mitty, HA
Parsons, RE
Cooper, JM
Ahn, J
机构
[1] Mt Sinai Med Ctr, Dept Radiol, New York, NY 10029 USA
[2] Mt Sinai Med Ctr, Dept Surg, New York, NY 10029 USA
关键词
aneurysm; aortic; iliac; arteries; grafts and prostheses; interventional procedures; stents and prostheses;
D O I
10.1148/radiology.209.1.9769820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate aortoiliac aneurysms repaired with endovascular stent-grafts complicated by hemodynamically significant graft stenosis. MATERIALS AND METHODS: Fifty-four patients (52 men, two women; age range, 41-90 years; mean age, 75 years) with aneurysms of the infrarenal aorta (n = 36) or iliac artery (n = 18) underwent repair by means of placement of an endovascular stent-graft. Technical success was evaluated angiographically during and after placement. At follow-up (range, 12-44 months), all patients underwent sequential duplex ultrasonography, helical computed tomography, and physical examination. RESULTS: Stent-grafts were placed successfully in all cases. Stenosis at the internal iliac arterial origin was identified at angiography in 17 patients (31%). Supplemental intragraft stents were placed in 11 patients, and stent-graft angioplasty alone was performed in one patient. Intragraft stents were placed percutaneously in five patients when stenosis was discovered during follow-up. CONCLUSION: Supplemental intragraft stents were required in 31% of aortoiliac endovascular stent-grafts to correct stent-graft stenosis and preserve long-term function. Placement of a fully supported stent-graft is necessary to repair an aortoiliac aneurysm.
引用
收藏
页码:111 / 116
页数:6
相关论文
共 22 条
[1]   Percutaneous treatment of a collapsed stent-graft [J].
Ahmad, AA ;
Najarian, KE ;
Morris, CS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (04) :637-639
[2]   Treatment of a failed bifurcated abdominal aortic stent graft with thrombolysis and wallstent placement [J].
Amesur, NB ;
Zajko, AB ;
Makaroun, MS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (05) :795-798
[3]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[4]  
Chuter TAM, 1997, J ENDOVASC SURG, V4, P13, DOI 10.1583/1074-6218(1997)004<0013:EEWASF>2.0.CO
[5]  
2
[6]  
CHUTER TAM, 1995, ENDOLUMINAL VASCULAR, P55
[7]  
Cragg A H, 1993, J Vasc Interv Radiol, V4, P455, DOI 10.1016/S1051-0443(93)71898-9
[8]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[9]  
Ivancev K, 1997, J ENDOVASC SURG, V4, P242, DOI 10.1583/1074-6218(1997)004<0242:AAAEWT>2.0.CO
[10]  
2