Combining ROPtool measurements of vascular tortuosity and width to quantify plus disease in retinopathy of prematurity

被引:31
作者
Cabrera, Michelle T.
Freedman, Sharon F.
Kiely, Amanda E.
Chiang, Michael F. [3 ,4 ]
Wallace, David K. [1 ,2 ]
机构
[1] Duke Univ, Sch Med, Dept Ophthalmol, Duke Eye Ctr,DUMC, Durham, NC 27710 USA
[2] Duke Univ, Sch Med, Dept Pediat, Duke Eye Ctr,DUMC, Durham, NC 27710 USA
[3] Columbia Univ Coll Phys & Surg, Dept Ophthalmol, New York, NY 10032 USA
[4] Columbia Univ Coll Phys & Surg, Dept Biomed Informat, New York, NY 10032 USA
来源
JOURNAL OF AAPOS | 2011年 / 15卷 / 01期
关键词
AGREEMENT; TRIAL;
D O I
10.1016/j.jaapos.2010.11.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND ROPtool is a computer program that is used to measure retinal vascular tortuosity and width. Our aim was to determine the best method for combining ROPtool's tortuosity and width values into an overall measure of plus disease. METHODS ROPtool was used to measure vessel tortuosity and width in 184 quadrants of 46 RetCam images of premature infants. Five methods for combining tortuosity and width were assessed: the plus index and sum of adjusted indices provide tortuosity and width values using different scales; tortuosity-weighted plus increases the contribution of width as tortuosity increases; the vessel area index is used to average vessel area per unit length; and regression analysis establishes a mathematical equation to fit expert diagnosis. For each method, receiver operating characteristic curves were generated with a 3-expert consensus as the reference standard. Optimal cut points for plus disease were selected and then tested on a second set of 184 quadrants of 46 different images. RESULTS When applied to the second data set, areas under the receiver operating characteristic curves were 0.857 for plus index, 0.918 for sum of adjusted indices, 0.941 for tortuosity-weighted plus, 0.868 for vessel area index, and 0.934 for regression analysis methods. The highest sensitivities and specificities were for tortuosity-weighted plus (85% for both) and regression analysis methods (85% and 86%, respectively). CONCLUSIONS When combining ROPtool's measures of width and tortuosity, sum of adjusted indices, tortuosity-weighted plus, and regression analysis methods had high overall accuracy. ROPtool can now generate a clinically meaningful quantitative description of vascular abnormality to aid in plus disease diagnosis. (J AAPOS 2011;15:40-44)
引用
收藏
页码:40 / 44
页数:5
相关论文
共 14 条
[1]  
[Anonymous], 1984, Br J Ophthalmol, V68, P690
[2]  
[Anonymous], 2000, PEDIATRICS, V105, P295
[3]  
[Anonymous], 2005, ARCH OPHTHALMOL, V123, P991
[4]  
[Anonymous], 1994, ARCH OPHTHALMOL, V112, P903
[5]   Interexpert agreement of plus disease diagnosis in retinopathy of prematurity [J].
Chiang, Michael F. ;
Jiang, Lei ;
Gelman, Rony ;
Du, Yunling E. ;
Flynn, John T. .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (07) :875-880
[6]  
Good William V, 2004, Trans Am Ophthalmol Soc, V102, P233
[7]   Computer-Assisted Measurement of Retinal Vascular Width and Tortuosity in Retinopathy of Prematurity [J].
Kiely, Amanda E. ;
Wallace, David K. ;
Freedman, Sharon F. ;
Zhao, Zheen .
ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (07) :847-852
[8]  
PALMER EA, 1988, ARCH OPHTHALMOL-CHIC, V106, P471
[9]   Telemedicine for Retinopathy of Prematurity Diagnosis: Evaluation and Challenges [J].
Richter, Grace M. ;
Williams, Steven L. ;
Starren, Justin ;
Flynn, John T. ;
Chiang, Michael F. .
SURVEY OF OPHTHALMOLOGY, 2009, 54 (06) :671-685
[10]   Agreement among pediatric ophthalmologists in diagnosing plus and pre-plus disease in retinopathy of prematurity [J].
Wallace, David K. ;
Quinn, Graham E. ;
Freedman, Sharon F. ;
Chiang, Michael F. .
JOURNAL OF AAPOS, 2008, 12 (04) :352-356