Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: Comparison with quantitative gated technetium 99m Sestamibi single photon emission computed tomography

被引:42
作者
Dawson, D
Rinkevich, D
Belcik, T
Jayaweera, AR
Rafter, P
Kaul, S
Wei, K
机构
[1] Univ Virginia, Med Ctr, Sch Med, Cardiovasc Imaging Ctr,Cardiovasc Div, Charlottesville, VA 22908 USA
[2] Philips Ultrasound, Andover, MA USA
关键词
D O I
10.1067/S0894-7317(03)00646-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The ability of high and low mechanical index (MI) imaging methods during myocardial contrast echocardiography (MCE) to assess the physiologic significance of coronary stenoses were compared with technetium 99m sestamibi single photon emission computed tomography (SPECT) in patients. Methods. Intermittent ultraharmonic imaging (high MI) and power modulation angio (low MI) were performed during continuous infusions of the echo-enhancing contrast agent, Optison, at rest and after dipyridamole stress in 39 patients. Technetium 99m sestamibi SPECT was performed simultaneously. images from the 3 apical windows were divided into 6 walls. Myocardial blood flow (MBF) velocity and MBF velocity reserve were quantified from pulsing interval versus acoustic intensity MCE curves in each wall using postprocessed images. Results: Approximately 25% of the myocardial walls could not be analyzed from MCE because of artifacts. MBF velocity and MBF derived from both MCE methods increased significantly after dipyridamole in healthy patients (n = 143 and 129 walls for high and low MI, respectively), compared with those with either reversible (n = 11 and 10 walls for high and low MI, respectively) or fixed defects (n = 18 and 14 walls for high and low MI, respectively) on SPECT. Consequently, MBF velocity and MBF reserve were significantly greater for patients with normal perfusion. Receiver operator characteristic curves obtained for MBF velocity reserve provided a sensitivity and specificity of 82% and 87%, respectively, for high MI; versus 64% and 96%, respectively, for low MI imaging after uninterpretable images were excluded from analysis. Conclusions. Both high and low MI MCE imaging techniques can be used to determine the presence of perfusion defects as identified by technetium 99m sestamibi SPECT. Low MI imaging methods have a number of drawbacks that limit its sensitivity compared with high MI techniques.
引用
收藏
页码:1171 / 1177
页数:7
相关论文
共 9 条
[1]   Role of capillaries in determining CBF reserve: new insights using myocardial contrast echocardiography [J].
Jayaweera, AR ;
Wei, K ;
Coggins, M ;
Bin, JP ;
Goodman, C ;
Kaul, S .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (06) :H2363-H2372
[2]   Myocardial contrast echocardiography: Basic principles [J].
Kaul, S .
PROGRESS IN CARDIOVASCULAR DISEASES, 2001, 44 (01) :1-11
[3]   Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography [J].
Leong-Poi, H ;
Le, E ;
Rim, SJ ;
Sakuma, T ;
Kaul, S ;
Wei, K .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (12) :1173-1182
[4]   Assessment of transmural distribution of myocardial perfusion with contrast echocardiography [J].
Linka, AZ ;
Sklenar, J ;
Wei, K ;
Jayaweera, AR ;
Skyba, DM ;
Kaul, S .
CIRCULATION, 1998, 98 (18) :1912-1920
[5]   QUANTIFICATION OF MYOCARDIAL PERFUSION WITH MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY DURING LEFT ATRIAL INJECTION OF CONTRAST - IMPLICATIONS FOR VENOUS INJECTION [J].
SKYBA, DM ;
JAYAWEERA, AR ;
GOODMAN, NC ;
ISMAIL, S ;
CAMARANO, G ;
KAUL, S .
CIRCULATION, 1994, 90 (03) :1513-1521
[6]   Quantitative gated single photon emission computed tomography imaging: A counts-based method for display and measurement of regional and global ventricular systolic function [J].
Smith, WH ;
Kastner, RJ ;
Calnon, DA ;
Segalla, D ;
Beller, GA ;
Watson, DD .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (06) :451-463
[7]  
Wei K, 2001, CIRCULATION, V103, P2560
[8]  
Wei K, 1998, CIRCULATION, V97, P473
[9]   Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion? [J].
Wei, K ;
Jayaweera, AR ;
Firoozan, S ;
Linka, A ;
Skyba, DM ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (01) :252-260