Validation of object-induced MR distortion correction for frameless stereotactic neurosurgery

被引:22
作者
Dean, D
Kamath, J
Duerk, JL
Ganz, E
机构
[1] Case Western Reserve Univ, Imaging Lab, Dept Neurol Surg, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
关键词
computed tomography (CT); craniofacial; fiducial; registration; susceptibility error;
D O I
10.1109/42.736049
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Spatial fidelity is a paramount issue in image guided neurosurgery. Until recently, three-dimensional computed tomography (3D CT) has been the primary modality because it provides fast volume capture with pixel level (1 mm) accuracy. While three-dimensional magnetic resonance (3D MR) images provide superior anatomic information, published image capture protocols are time consuming and result in scanner- and object-induced magnetic field inhomogeneities which raise inaccuracy above pixel size, Using available scanner calibration software, a volumetric algorithm to correct for object-based geometric distortion, and a Fast Low Angle SHot (FLASH) 3D MR-scan protocol, we were able to reduce mean CT to MR skin-adhesed fiducial marker registration error from 1.36 to 1.09 mm, After dropping the worst one or two of six fiducial markers, mean registration error dropped to 0.62 mm (subpixel accuracy), Three dimensional object-induced error maps present highest 3D MR spatial infidelity at the tissue interfaces (skin/air, scalp/skull) where frameless stereotactic fiducial markers are commonly applied. The algorithm produced similar results in two patient 3D MR-scans.
引用
收藏
页码:810 / 816
页数:7
相关论文
共 42 条
[1]   MAGNETIC-RESONANCE IMAGE-DIRECTED STEREOTAXIC NEUROSURGERY - USE OF IMAGE FUSION WITH COMPUTERIZED-TOMOGRAPHY TO ENHANCE SPATIAL ACCURACY [J].
ALEXANDER, E ;
KOOY, HM ;
VANHERK, M ;
SCHWARTZ, M ;
BARNES, PD ;
TARBELL, N ;
MULKERN, RV ;
HOLUPKA, EJ ;
LOEFFLER, JS .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :271-276
[2]   MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames [J].
Burchiel, KJ ;
Nguyen, TT ;
Coombs, BD ;
Szumoski, J .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 (1-3) :123-136
[3]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[4]   TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[5]  
CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149
[6]  
Dean D, 1997, LECT NOTES COMPUT SC, V1230, P393
[7]  
DORMONT D, 1994, AM J NEURORADIOL, V15, P365
[8]  
Duquesnel J, 1995, Acta Neurochir Suppl, V63, P16
[9]  
FIEG E, 1986, PHYS MED BIOL, V31, P1091
[10]   HEPARAN-SULFATE PROTEOGLYCANS [J].
GALLAGHER, JT ;
TURNBULL, JE ;
LYON, M .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1990, 18 (02) :207-209