Performance analysis of photovoltaic-thermal collector by explicit dynamic model

被引:571
作者
Chow, TT [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1016/j.solener.2003.07.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 [动力工程及工程热物理]; 0820 [石油与天然气工程];
摘要
Although the performance of hybrid photovoltaic-thermal (PV/T) collector had been studied both experimentally and numerically for some years, the thermal models developed in previous studies were mostly steady-state models for predicting the annual yields. The operation of a PV/T collector is inherently dynamic. A steady-state model is not suitable for predicting working temperatures of the PV module and the heat-removal fluid during periods of fluctuating irradiance or intermittent fluid flow. Based on the control-volume finite-difference approach, an explicit dynamic model was developed for a single-glazed flat-plate water-heating PV/T collector. A transport delay fluid flow model was incorporated. The proposed model is suitable for dynamic system simulation applications. It allows detailed analysis of the transient energy flow across various collector components and captures the instantaneous energy outputs. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 14 条
[1]
Model calculations on a flat-plate solar heat collector with integrated solar cells [J].
Bergene, T ;
Lovvik, OM .
SOLAR ENERGY, 1995, 55 (06) :453-462
[3]
Clarke J. A., 2001, Energy Simulation in Building Design, V2nd, DOI DOI 10.4324/9780080505640
[4]
Duffie J.A., 2006, SOLAR ENG THERMAL PR, VThird
[5]
Dw J.H., 1977, Coop Mediterr Pour L'energie Solaire, Rev Int D'heliotechnique, V2, P56
[6]
EXTENSION OF THE HOTTEL-WHILLIER MODEL TO THE ANALYSIS OF COMBINED PHOTOVOLTAIC THERMAL FLAT-PLATE COLLECTORS [J].
FLORSCHUETZ, LW .
SOLAR ENERGY, 1979, 22 (04) :361-366
[7]
SOME ASPECTS OF A PV/T COLLECTOR FORCED CIRCULATION FLAT-PLATE SOLAR WATER-HEATER WITH SOLAR-CELLS [J].
GARG, HP ;
AGARWAL, RK .
ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (02) :87-99
[8]
FREE CONVECTIVE HEAT-TRANSFER ACROSS INCLINED AIR LAYERS [J].
HOLLANDS, KGT ;
UNNY, TE ;
RAITHBY, GD ;
KONICEK, L .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (02) :189-193
[9]
Holman J. P., 1989, Heat Transfer
[10]
Performance evaluation of solar photovoltaic/thermal systems [J].
Huang, BJ ;
Lin, TH ;
Hung, WC ;
Sun, FS .
SOLAR ENERGY, 2001, 70 (05) :443-448