End-user errors in applying two malaria rapid diagnostic tests in a remote area of Sudan

被引:37
作者
Seidahmed, Osama M. E. [1 ]
Mohamedein, Muneir M. N. [2 ]
Elsir, Afrah A. [3 ]
Ali, Fayez T. [1 ]
Malik, El Fatih M. [1 ]
Ahmed, Eldirdieri S. [4 ]
机构
[1] Natl Malaria Control Program, Khartoum, Sudan
[2] Univ Khartoum, Fac Med, Lab Sci, Khartoum, Sudan
[3] Univ Gezira, Inst Nucl Med Mol Biol & Oncol, Gezira, Sudan
[4] Univ Juba, Coll Med, Juba, Sudan
关键词
Core Malaria Pf test; OptiMAL test; user practices; error; Sudan;
D O I
10.1111/j.1365-3156.2008.02015.x
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
We assessed end-user practice for numerous procedural steps of two types of RDTs: Core Malaria Pf (TM) (the cassette format) and OptiMAL IT (TM) (the dipstick format). Two types of errors occurred: generic errors common to both types of test and specific errors caused by the test design and manufacturer's instructions. End-user errors were more frequent with OptiMAL IT (TM) than Core Pf (TM) tests. To improve malaria diagnosis with rapid tests, users require training and better manufacturer's instructions that take into account local conditions.
引用
收藏
页码:406 / 409
页数:4
相关论文
共 10 条
[1]   Ensuring quality and access for malaria diagnosis: how can it be achieved? [J].
Bell, David ;
Wongsrichanalai, Chansuda ;
Barnwell, John W. .
NATURE REVIEWS MICROBIOLOGY, 2006, 4 (09) :682-695
[2]   Performance of the OptiMAL® assay for detection and identification of malaria infections in asymptomatic residents of Irian Jaya, Indonesia [J].
Fryauff, DJ ;
Purnomo ;
Sutamihardja, MA ;
Elyazar, IRS ;
Susanti, I ;
Krisin ;
Subianto, B ;
Marwoto, H .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2000, 63 (3-4) :139-145
[3]   MalaQuick™ versus ParaSight F® as a diagnostic aid in travellers' malaria [J].
Funk, M ;
Schlagenhauf, P ;
Tschopp, A ;
Steffen, R .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1999, 93 (03) :268-272
[4]   Use of dipstick tests for the rapid diagnosis of malaria in nonimmune travelers [J].
Jelinek, T ;
Grobusch, MP ;
Nothdurft, HD .
JOURNAL OF TRAVEL MEDICINE, 2000, 7 (04) :175-179
[5]   Application of the ParaSight™-F dipstick test for malaria diagnosis in a district control program [J].
Kilian, AHD ;
Kabagambe, G ;
Byamukama, W ;
Langi, P ;
Weis, P ;
von Sonnenburg, F .
ACTA TROPICA, 1999, 72 (03) :281-293
[6]   Minimising human error in malaria rapid diagnosis: clarity of written instructions and health worker performance [J].
Rennie, Waverly ;
Phetsouvanh, Rattanaxay ;
Lupisan, Socorro ;
Vanisaveth, Viengsay ;
Hongvanthong, Bouasy ;
Phompida, Sarnlane ;
Alday, Portia ;
Fulache, Mila ;
Lumagui, Richard ;
Jorgensen, Pernille ;
Bell, David ;
Harvey, Steven .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2007, 101 (01) :9-18
[7]  
TAVROW P, 2000, USING QUALITY DESIGN
[8]   Feasibility of a rapid dipstick antigen-capture assay for self-testing of travellers' malaria [J].
Trachsler, M ;
Schlagenhauf, P ;
Steffen, R .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 1999, 4 (06) :442-447
[9]   Self-testing for falciparum malaria with antigen-capture cards by travelers with symptoms of malaria [J].
Whitty, CJM ;
Armstrong, M ;
Behrens, RH .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2000, 63 (5-6) :295-297
[10]  
World Health Organization (WHO), 2006, US MAL RAP DIAGN TES