Reliability and responsiveness of elbow trajectory tracking in chronic poststroke hemiparesis

被引:44
作者
Patten, C
Kothari, D
Whitney, J
Lexell, J
Lum, PS
机构
[1] Dept Vet Affairs VA Palo Alto Hlth Care Syst, Rehabil Res & Dev Ctr 153, Palo Alto, CA 94304 USA
[2] Stanford Univ, Sch Med, Dept Orthopaed Surg, Stanford, CA 94305 USA
[3] Univ Lund Hosp, Dept Rehabil, S-22185 Lund, Sweden
[4] Virginia Commonwealth Univ, Dept Biomed Engn, Richmond, VA USA
关键词
motor control; outcome; rehabilitation; reliability; responsiveness; stroke;
D O I
10.1682/JRRD.2003.11.0487
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
This study established the reliability of a novel upper-limb trajectory-tracking task for assessment of perceptual motor control in hemiparetic adults. Eleven persons with chronic poststroke hemiparesis (mean 58.6 months) and eleven nondisabled control subjects performed an elbow flexion-extension task against a low-resistance isotonic load at three speeds: 25degrees/s, 45degrees/s, and 65degrees/s. Both arms (paretic and nonparetic or dominant and nondominant) were tested during two identical sessions separated by 1 week. Relative reliability (intraclass correlation coefficient [ICC]) ranged from 0.5 to 0.8 and absolute reliability (standard error of measurement [SEM%]) ranged between 19% to 36% across both subject groups. No systematic errors between test sessions were revealed. Smallest real differences (SRDs) were determined to be +/-2degrees to 3degrees in nondisabled, +/-2degrees to 5degrees in nonparetic and +/-9degrees in paretic arms. Responsiveness ratios derived with the use of the SRDs ranged between 1.91 to 2.45, indicating that this instrument is sensitive to clinically important change and suitable for demonstrating effects on upper-limb motor performance following clinical intervention.
引用
收藏
页码:487 / 500
页数:14
相关论文
共 30 条
[1]   The nature of the loss of strength and dexterity in the upper limb following stroke [J].
Ada, L ;
ODwyer, N ;
Green, J ;
Yeo, W ;
Neilson, P .
HUMAN MOVEMENT SCIENCE, 1996, 15 (05) :671-687
[2]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[3]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]   Maximal grip force in chronic stroke subjects and its relationship to global upper extremity function [J].
Boissy, P ;
Bourbonnais, D ;
Carlotti, MM ;
Gravel, D ;
Arsenault, BA .
CLINICAL REHABILITATION, 1999, 13 (04) :354-362
[5]   Stimulus-response compatibility: Effects in a manual tracking task [J].
Carey, JR ;
Bogard, CL ;
Youdas, JW ;
Suman, VJ .
PERCEPTUAL AND MOTOR SKILLS, 1995, 81 (03) :1155-1170
[6]  
Deyo RA, 1991, CONTROLLED CLIN TRIA, V12, P142
[7]   Reliability of lower extremity strength measures in persons with chronic stroke [J].
Eng, JJ ;
Kim, CM ;
MacIntyre, DL .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (03) :322-328
[8]   Reliability and comparison of weight-bearing ability during standing tasks for individuals with chronic stroke [J].
Eng, JJ ;
Chu, KS .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08) :1138-1144
[9]   Maximum voluntary weight-bearing by the affected and unaffected legs in standing following stroke [J].
Goldie, PA ;
Matyas, TA ;
Evans, OM ;
Galea, M ;
Bach, TM .
CLINICAL BIOMECHANICS, 1996, 11 (06) :333-342
[10]   AGONIST AND ANTAGONIST ACTIVITY DURING VOLUNTARY UPPER-LIMB MOVEMENT IN PATIENTS WITH STROKE [J].
GOWLAND, C ;
DEBRUIN, H ;
BASMAJIAN, JV ;
PLEWS, N ;
BURCEA, I .
PHYSICAL THERAPY, 1992, 72 (09) :624-633