Preparative separation of isoflavone components in soybeans using high-speed counter-current chromatography

被引:42
作者
Du, QZ
Li, ZH
Ito, Y [1 ]
机构
[1] NHLBI, Biophys Chem Lab, NIH, Bethesda, MD 20892 USA
[2] Hunan Agr Univ, Coll Food Sci & Technol, Changsha 410008, Peoples R China
[3] Hangzhou Univ Commerce, Inst Food & Biol Engn, Hangzhou 310035, Peoples R China
关键词
counter-current chromatography; preparative chromatography; soybean; isoflavones;
D O I
10.1016/S0021-9673(01)01031-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Four isoflavone components were purified from soybean extract by high-speed counter-current chromatography (HSCCC). Two types of multilayer coil separation columns were used: a small column made of standard 2.6-mm I.D. PTFE (polytetrafluoroethylene) tubing with a 260-ml capacity and a large column of convoluted PTFE tubing of 5.7-mm average I.D. with a 1200-ml capacity. Separation was performed with a two-phase solvent system composed of hexane-ethyl acetate-1-butanol-methanol-acetic acid-water (1:2:1:1:5:1, v/v) by eluting the lower aqueous phase at 2 ml/min (small column) and 5 ml/min (large column) at a revolution speed of 700 rpm. From 500 mg of crude sample the small column yielded 33 mg of daidzin, 41 mg of genistin, 27 mg of 6 " -O-malonyldaidzin and 24 mg of 6 " -O-malonylgenistin. The large convoluted column separated, from 3 g of crude sample, 203 mg of daidzin., 241 mg of genistin, 158 mg of 6 "O-malonyldaidzin and 135 mg of 6 " -O-malonylgenistin all at over 90% purity. The convoluted tubing facilitated preparation of a large multilayer coil due to its high flexibility. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 274
页数:4
相关论文
共 7 条
  • [1] METAANALYSIS OF THE EFFECTS OF SOY PROTEIN-INTAKE ON SERUM-LIPIDS
    ANDERSON, JW
    JOHNSTONE, BM
    COOKNEWELL, ME
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (05) : 276 - 282
  • [2] Bahram H.A., 1996, J NUTR, V126, P161
  • [3] Low speed rotary countercurrent chromatography using a convoluted multilayer helical tube for industrial separation
    Du, QZ
    Wu, PD
    Ito, Y
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3363 - 3365
  • [4] ITO Y, 1986, CRIT REV ANAL CHEM, V17, P65, DOI 10.1080/10408348608542792
  • [5] Ito Y., 1996, High-Speed Countercurrent Chromatography
  • [6] JIANG H, 2000, CHIN J FOOD SCI, V21, P56
  • [7] THE ROLE OF SOY PRODUCTS IN REDUCING RISK OF CANCER
    MESSINA, M
    BARNES, S
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1991, 83 (08): : 541 - 546