Volatile organo-selenium speciation in biological matter by solid phase microextraction-moderate temperature multicapillary gas chromatography with microwave induced plasma atomic emission spectrometry detection

被引:57
作者
Dietz, C [1 ]
Landaluze, JS [1 ]
Ximénez-Embún, P [1 ]
Madrid-Albarrán, Y [1 ]
Cámara, C [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
solid phase microextraction; microwave induced plasma emission spectroscopy; organo-selenium compounds; multicapillary columns; lupine; yeast; Indian mustard; garlic; chemometrics;
D O I
10.1016/j.aca.2003.09.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave induced plasma atomic emission spectrometry (MIP-AES) in combination with multicapillary (MC) gas chromatography could be proven to be useful for element specific detection of volatile species. Solid phase microextraction (SPME) was used for preconcentration and sample-matrix separation. The fiber desorption unit as well as the heating control for the MC column were in-house developed and multicapillary column was operated at moderate temperatures (30-100degreesC). The method was optimized for organo-selenium species (dimethylselenide (DMSe), diethylselenide (DEtSe) and dimethyldiselenide (DMDSe)), using a chemometric approach. Stationary phases for the separation column were optimized using a conventional GC and contrasted with the results obtained with the MC. Application was focussed on selenium accumulating biological matter, such as lupine, yeast, Indian mustard and garlic. These samples were grown in hydroponic solution containing inorganic selenium (Na2SeO3 and Na2SeO4). SPME sampling was carried out in fixed volume flow boxes in headspace above the living plants and in vials using treated samples. Results demonstrate inorganic selenium transformation into volatile organic species during metabolism. Separation is fast, a chromatogram can be obtained in less than 3 min and detection limits were at sub-ppb level for all investigated species. The system is independent from the use of a conventional gas chromatographic oven and can be used as a versatile alternative to highly cost intensive methods such as GC-ICP-MS. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 39 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
BARKER TB, 1994, QUALITY EXPT DESIGN
[3]   Allium chemistry: Natural abundance of organoselenium compounds from garlic, onion and related plants and in human garlic breath [J].
Block, E ;
Cai, XJ ;
Uden, PC ;
Zhang, X ;
Quimby, BD ;
Sullivan, JJ .
PURE AND APPLIED CHEMISTRY, 1996, 68 (04) :937-944
[4]   SAMPLE INTRODUCTION DEVICE FOR USE WITH A MICROWAVE-INDUCED PLASMA [J].
BROOKS, EI ;
TIMMINS, KJ .
ANALYST, 1985, 110 (05) :557-558
[5]   ALLIUM CHEMISTRY - IDENTIFICATION OF SELENOAMINO ACIDS IN ORDINARY AND SELENIUM-ENRICHED GARLIC, ONION, AND BROCCOLI USING GAS-CHROMATOGRAPHY WITH ATOMIC-EMISSION DETECTION [J].
CAI, XJ ;
BLOCK, E ;
UDEN, PC ;
ZHANG, X ;
QUIMBY, BD ;
SULLIVAN, JJ .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (07) :1754-1757
[6]  
CAMARA C, 1995, QUALITY ASSURANCE EN, P235
[7]   Sol-gel coating technology for the preparation of solid-phase microextraction fibers of enhanced thermal stability [J].
Chong, SL ;
Wang, DX ;
Hayes, JD ;
Wilhite, BW ;
Malik, A .
ANALYTICAL CHEMISTRY, 1997, 69 (19) :3889-3898
[8]  
CRAIG PJ, 1986, ORGANOMETALLIC COMPO, P30
[9]  
Davies L, 1993, EFFICIENCY RES DEV P
[10]  
Deming SN., 1993, EXPT DESIGN CHEMOMET, DOI DOI 10.1016/j.plaphy.2010.08.016