Painful paresthesiae are infrequent during brachial plexus localization using low-current peripheral nerve stimulation

被引:22
作者
Karaca, P
Hadzic, A
Yufa, M
Vloka, JD
Brown, AR
Visan, A
Sanborn, K
Santos, AC
机构
[1] Columbia Univ, Coll Phys & Surg, St Lukes Roosevelt Hosp Ctr, Dept Anesthesiol, New York, NY USA
[2] Columbia Univ, Coll Phys & Surg, Columbia Presbyterian Med Ctr, Dept Anesthesiol, New York, NY USA
关键词
regional anesthesia; nerve block; nerve stimulator;
D O I
10.1016/j.rapm.2003.08.004
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Considerable controversy exists over the relationship of paresthesia to nerve stimulation. The purpose of this study was to determine the frequency with which patients report paresthesia at the point that an acceptable motor response is obtained to low-intensity current electrical stimulation. Methods: Low-intensity current nerve stimulation (0.6 mA, 200 microseconds, 2 Hz) was used to identify the brachial plexus in 64 consecutive patients having shoulder or arm surgery with an interscalene block. During nerve localization and while maintaining a motor response (0.20 mA-0.40 mA), the patients were queried regarding any radiating sensation or pain (paresthesia) in the shoulder or extremity on the side of the blockade. Sensory distribution of the block, motor strength of the arm muscles, and adequacy of anesthesia were used to assess the extent of blockade. Results: Ninety-five percent of patients had satisfactory surgical anesthesia. None of the patients spontaneously reported having a paresthesia during nerve stimulation. However, on careful questioning, half of the patients (55%) reported electrical paresthesia, defined as dull tingling sensation traveling down to their hands and coinciding with the motor response. in addition, most patients (71%) spontaneously reported having a mild, radiating paresthesia on initial injection of local anesthetic. Conclusions: Painful paresthesiae should be infrequent when a low-stimulating current is used to identify the neural components of the brachial plexus and when the block needle is advanced slowly. Low-current intensity nerve stimulation can be used to achieve successful interscalene block with minimal discomfort to the patient.
引用
收藏
页码:380 / 383
页数:4
相关论文
共 12 条
[1]  
Bathram CN, 1997, ANAESTHESIA, V52, P761
[2]   Fascicular anatomy, nervi nervorum, and paresthesia [J].
Carrero, G .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2003, 28 (01) :72-73
[3]   What is the relationship between paresthesia and nerve stimulation for axillary brachial plexus block? [J].
Choyce, A ;
Chan, VWS ;
Middleton, WJ ;
Knight, PR ;
Peng, P ;
McCartney, CJL .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2001, 26 (02) :100-104
[4]  
Hadzic A, 2000, ANESTH ANALG, V91, P1306
[5]   Nerve stimulators used for peripheral nerve blocks vary in their electrical characteristics [J].
Hadzic, A ;
Vloka, J ;
Hadzic, N ;
Thys, DM ;
Santos, AC .
ANESTHESIOLOGY, 2003, 98 (04) :969-974
[6]   Unsolicited Paresthesias with nerve stimulator: Case reports of four patients [J].
Mulroy, MF ;
Mitchell, B .
ANESTHESIA AND ANALGESIA, 2002, 95 (03) :762-763
[7]   Brachial plexus anesthesia: Essentials of our current understanding [J].
Neal, JM ;
Hebl, JR ;
Gerancher, JC ;
Hogan, QH .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (04) :402-428
[8]  
Pither CE., 1985, REGION ANESTH PAIN M, V10, P49
[9]   Rat peripheral nerve components release calcitonin gene-related peptide and prostaglandin E2 in response to noxious stimuli:: Evidence that nervi nervorum are nociceptors [J].
Sauer, SK ;
Bove, GM ;
Averbeck, B ;
Reeh, PW .
NEUROSCIENCE, 1999, 92 (01) :319-325
[10]   Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration [J].
Urmey, WF ;
Stanton, J .
ANESTHESIOLOGY, 2002, 96 (03) :552-554