Predictors of airborne endotoxin in the home

被引:134
作者
Park, JH
Spiegelman, DL
Gold, DR
Burge, HA
Milton, DK
机构
[1] Harvard Univ, Sch Publ Hlth, Occupat Hlth Program, Dept Environm Hlth, Boston, MA 02115 USA
[2] Harvard Univ, Sch Publ Hlth, Dept Epidemiol, Boston, MA 02115 USA
[3] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Dept Med, Channing Lab, Boston, MA USA
[5] Harvard Univ, Sch Med, Boston, MA USA
关键词
airborne endotoxin; dust endotoxin; predictive model; seasonal variability;
D O I
10.2307/3454831
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We identified home characteristics associated with the level of airborne endotoxin in 111 Boston-area homes enrolled in a cohort study of home exposures and childhood asthma, and we developed a predictive model to estimate airborne endotoxin. We measured endotoxin in family-room air and in dust from the baby's bed, family room, bedroom, and kitchen floor. Level of airborne endotoxin was weakly correlated (r < 0.3) with level of endotoxin in each of the four types of dust samples and was significantly correlated with endotoxin in family-room dust (p < 0.05). Endotoxin in family-room dust accounted for < 6% of the variability of airborne endotoxin. In a multivariate model, certain home characteristics were positively (p < 0.05) associated with airborne endotoxin. These included current presence of dog (difference in level, dog vs. no dog = 72%, partial R-2 = 12.8%), past presence of dog (partial R-2 = 5.5%), and endotoxin level in family-room dust (partial R-2 = 5.3%). Use of a dehumidifier (partial R-2 = 6.4%) was negatively associated (p = 0.02; difference = -31%) with airborne endotoxin. Other home characteristics were identified as important determinants of increased airborne endotoxin in this model, but individual coefficients were not statistically significant (alpha = 0.05): total amount of fine dust collected in the home (partial R-2 = 3.8%), concrete floor in family room (3.7%), water damage (3.6%), and use of cool-mist humidifier in past year (2.7%). This multivariate model explained 42% of the variability of airborne endotoxin levels, a substantial improvement over that with dust endotoxin alone. Airborne endotoxin in Boston-area homes appears to be determined by the presence of dogs, moisture sources, and increased a-mounts of settled dust.
引用
收藏
页码:859 / 864
页数:6
相关论文
共 39 条
[1]   MEAN SQUARE ERROR OF PREDICTION AS A CRITERION FOR SELECTING VARIABLES [J].
ALLEN, DM .
TECHNOMETRICS, 1971, 13 (03) :469-&
[2]   HOME DAMPNESS AND RESPIRATORY MORBIDITY IN CHILDREN [J].
BRUNEKREEF, B ;
DOCKERY, DW ;
SPEIZER, FE ;
WARE, JH ;
SPENGLER, JD ;
FERRIS, BG .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (05) :1363-1367
[3]  
Carroll RJ., 1995, MEASUREMENT ERROR NO
[4]   INHALED ENDOTOXIN AND DECREASED SPIROMETRIC VALUES - AN EXPOSURE RESPONSE RELATION FOR COTTON DUST [J].
CASTELLAN, RM ;
OLENCHOCK, SA ;
KINSLEY, KB ;
HANKINSON, JL .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (10) :605-610
[5]  
Christiani DC, 1999, AM J IND MED, V35, P321, DOI 10.1002/(SICI)1097-0274(199904)35:4<321::AID-AJIM1>3.0.CO
[6]  
2-L
[7]   Endotoxin and β(1→3)-glucan in house dust and the relation with home characteristics:: A pilot study in 25 German houses [J].
Douwes, J ;
Doekes, G ;
Heinrich, J ;
Koch, A ;
Bischof, W ;
Brunekreef, B .
INDOOR AIR, 1998, 8 (04) :255-263
[8]  
DOUWES J, 1998, RESP HLTH EFFECTS IN, P109
[9]   Predictors of repeated wheeze in the first year of life - The relative roles of cockroach, birth weight, acute lower respiratory illness, and maternal smoking [J].
Gold, DR ;
Burge, HA ;
Carey, V ;
Milton, DK ;
Platts-Mills, T ;
Weiss, ST .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (01) :227-236
[10]   Bacterial endotoxin is an active component of cigarette smoke [J].
Hasday, JD ;
Bascom, R ;
Costa, JJ ;
Fitzgerald, T ;
Dubin, W .
CHEST, 1999, 115 (03) :829-835