Soft capacitive sensor for structural health monitoring of large-scale systems

被引:84
作者
Laflamme, S. [1 ]
Kollosche, M. [2 ]
Connor, J. J. [1 ]
Kofod, G. [2 ]
机构
[1] MIT, Dept Civil & Environm Engn, Cambridge, MA 02139 USA
[2] Univ Potsdam, Inst Phys & Astron, D-14476 Potsdam, Germany
关键词
large-scale system; structural health monitoring; strain monitoring; capacitive sensor; dielectric polymer; stretchable sensor;
D O I
10.1002/stc.426
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Structural integrity of infrastructures can be preserved if damage is diagnosed, localized, and repaired in time. During the past decade, there has been a considerable effort to automate the process of structural health monitoring, which is complicated by the inherent large size of civil structures. Hence, a need has arisen to develop new approaches that enable more effective health monitoring. In this paper, a new sensing technique for damage localization on large civil structures is proposed. Specifically, changes in strain are detected using a capacitance sensor built with a soft, stretchable dielectric polymer with attached stretchable metal film electrodes. A change in strain causes a measurable change in the capacitance of the sensor, which can be directly monitored when the sensor is fixed to a structure. The proposed method is shown here to permit an accurate detection of cracks. The proposed system deploys a layer of dielectric polymer on the surface of a structural element, and regularly monitors any change in capacitance, giving in turn information about the structural state. The smart material is composed of inexpensive silicone elastomers, which make the monitoring system a promising application for large surfaces. Results from tests conducted on small- scale specimens showed that the technology is capable of detecting cracks, and tests conducted on large- size specimens demonstrated that several sensor patches organized on a sensor sheet are capable of localizing a crack. The sensor strain also exhibits a high correlation with the loss of stiffness. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:70 / 81
页数:12
相关论文
共 17 条
[1]  
[Anonymous], 2009, ELECTROACTIVE POLYM, DOI DOI 10.1117/12.815741
[2]   Mechanical properties of Dielectric Elastomer Actuators with smart metallic compliant electrodes [J].
Benslimane, M ;
Gravesen, P .
SMART STRUCTURES AND MATERIALS 2002: ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD), 2002, 4695 :150-157
[3]  
Bungey J.H., 1996, TESTING CONCRETE STR
[4]   Crack detection of a full-scale reinforced concrete girder with a distributed cable sensor [J].
Chen, GD ;
Sun, SS ;
Pommerenke, D ;
Drewniak, JL ;
Greene, GG ;
McDaniel, RD ;
Belarbi, A ;
Mu, HM .
SMART MATERIALS & STRUCTURES, 2005, 14 (03) :S88-S97
[5]   Less can be more - Holes in polymers lead to a new paradigm of piezoelectric materials for electret transducers [J].
Gerhard-Multhaupt, R .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (05) :850-859
[6]  
GIURGIUTIU V, 2009, ENCY STRUCTURAL HLTH, P981
[7]  
Kabhari V.M., 2009, ENCY STRUCTURAL HLTH, P1467
[8]  
Laflamme S, 2010, P 5WCSCM TOK JAP
[9]  
Lin B, 2007, P SOC PHOTO-OPT INS, V6529, p65290I
[10]  
Lin B, 2009, P SOC PHOTO-OPT INS, V7292, p72921M