On the efficiency of stereologic volumetry as commonly implemented for three-dimensional digital images

被引:4
作者
Black, KJ
机构
[1] Washington Univ, Sch Med, Dept Psychiat, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Neurol & Neurol Surg, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
image processing; computer-assisted; stereology; volumetry; magnetic resonance imaging;
D O I
10.1016/S0925-4927(99)00003-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The aim of the study was to demonstrate, for certain ideal shapes (right cylinders) and for representative neuroanatomical images, that stereologic volumetry of three-dimensional images is more efficient when the sampling grid is placed randomly on each cross-section rather than identically across sections. As an example, the special case of mathematical right cylinders is presented, and an informal proof is provided. For neuroanatomical images, a custom computer program estimated volume with either the fixed- or random-grid method, using the same cross-sectional slices and first-slice test grid position for each method. The slice spacing, grid size, and starting grid position were randomly varied within practical constraints for 100 000 trials in each image. For right cylinders, the random-grid method is always more efficient than the fixed-grid method. For the neuroanatomic images tested, relative variance was up to three times higher for the fixed-grid method than for the random-grid method, especially for test grids with few grid intersections ('hits') per section. With the random-grid method, relative variance is primarily dependent on the total number of hits rather than on the distribution of hits per section. Implementation of the random-grid method for stereologic volumetry in three-dimensional images should in general improve sampling efficiency. (C) 1999 Elsevier Science Ireland Ltd. All rights resented.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 21 条
[1]   Baboon basal ganglia stereotaxy using internal MRI landmarks: Validation and application to PET imaging [J].
Black, KJ ;
Gado, MH ;
Videen, TO ;
Perlmutter, JS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) :881-886
[2]   Putamen volume in idiopathic focal dystonia [J].
Black, KJ ;
Ongur, D ;
Perlmutter, JS .
NEUROLOGY, 1998, 51 (03) :819-824
[3]   Fetal and fetal organ volume estimations with magnetic resonance imaging [J].
Garden, AS ;
Roberts, N .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (02) :442-448
[4]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[5]   THE EFFICIENCY OF SYSTEMATIC-SAMPLING IN STEREOLOGY AND ITS PREDICTION [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 147 :229-263
[6]   STEREOLOGY - THE FAST LANE BETWEEN NEUROANATOMY AND BRAIN-FUNCTION - OR STILL ONLY A TIGHTROPE [J].
GUNDERSEN, HJG .
ACTA NEUROLOGICA SCANDINAVICA, 1992, 85 :8-13
[7]  
HALLER J, 1994, P SOC PHOTO-OPT INS, V2359, P660
[8]   MAGNETIC-RESONANCE IMAGE BASED HIPPOCAMPAL VOLUMETRY - CORRELATION WITH OUTCOME AFTER TEMPORAL LOBECTOMY [J].
JACK, CR ;
SHARBROUGH, FW ;
CASCINO, GD ;
HIRSCHORN, KA ;
OBRIEN, PC ;
MARSH, WR .
ANNALS OF NEUROLOGY, 1992, 31 (02) :138-146
[9]   A COMPARISON OF STEREOLOGY AND SEGMENTATION TECHNIQUES FOR VOLUMETRIC MEASUREMENTS OF LATERAL VENTRICLES IN MAGNETIC-RESONANCE-IMAGING [J].
KESHAVAN, MS ;
ANDERSON, S ;
BECKWITH, C ;
NASH, K ;
PETTEGREW, JW ;
KRISHNAN, KRR .
PSYCHIATRY RESEARCH-NEUROIMAGING, 1995, 61 (01) :53-60
[10]  
KRISHNAN KRR, 1993, DEPRESSION, V1, P159