MR enteroclysis protocol optimization: comparison between 3D FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences

被引:70
作者
Gourtsoyiannis, N [1 ]
Papanikolaou, N [1 ]
Grammatikakis, J [1 ]
Maris, T [1 ]
Prassopoulos, P [1 ]
机构
[1] Univ Crete, Univ Hosp Heraklion, Dept Radiol, Fac Med, Iraklion 71110, Greece
关键词
MRI; true FISP; small bowel; Crohn's disease; enteroclysis;
D O I
10.1007/s003300000805
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to introduce the true fast imaging with steady-state precession (FISP) sequence for MR enteroclysis and compare it with the already used T1-weighted fast low-angle shot (FLASH) sequence. Twenty-one patients underwent both MR and conventional enteroclysis. The MR enteroclysis examination was performed after administration of an iso-osmotic water solution through a nasojejunal catheter and the following sequences were included: (a) true FISP; and (b) 3D FLASH with fat saturation after intravenous injection of 20 mg Buscopan or 1 mg glucagon and 0.1 mmol/kg gadolinium chelates. The true FISP sequence provided images with significantly fewer motion artifacts, whereas 3D FLASH was less sensitive to susceptibility and chemical shift artifacts. The homogeneity of endoluminal opacification, wall conspicuity, and distention of the small bowel were very good to excellent and the two sequences presented no statistically significant differences here. True FISP provided significantly better overall image quality than did 3D FLASH. The true FISP sequence can provide good anatomic demonstration of the small bowel on T2-like images and could be combined with T1-weighted FLASH images for an integrated protocol of MR enteroclysis.
引用
收藏
页码:908 / 913
页数:6
相关论文
共 19 条
[1]   MR-IMAGING OF CROHN DISEASE - USE OF PERFLUBRON AS A GASTROINTESTINAL CONTRAST AGENT [J].
ANDERSON, CM ;
BROWN, JJ ;
BALFE, DM ;
HEIKEN, JP ;
BORRELLO, JA ;
CLOUSE, RE ;
PILGRAM, TK .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :491-496
[2]   THE SMALL-BOWEL ENEMA - A 10 YEAR REVIEW [J].
DIXON, PM ;
ROULSTON, ME ;
NOLAN, DJ .
CLINICAL RADIOLOGY, 1993, 47 (01) :46-48
[3]   Breath-hold fast spin-echo MR imaging of Crohn's disease [J].
Ernst, O ;
Asselah, T ;
Cablan, X ;
Sergent, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (01) :127-128
[4]   Pathologic conditions in the small bowel: Findings at fat-suppressed gadolinium-enhanced MR imaging with an optimized suspension of oral magnetic particles [J].
Faber, SC ;
Stehling, MK ;
Holzknecht, N ;
Gauger, J ;
Helmberger, T ;
Reiser, M .
RADIOLOGY, 1997, 205 (01) :278-282
[5]   LYMPHOMA OF THE SMALL-INTESTINE - RADIOLOGICAL APPEARANCES [J].
GOURTSOYIANNIS, NC ;
NOLAN, DJ .
CLINICAL RADIOLOGY, 1988, 39 (06) :639-645
[6]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[7]   Blueberry juice used per os in upper abdominal MR imaging: composition and initial clinical data [J].
Karantanas, AH ;
Papanikolaou, N ;
Kalef-Ezra, J ;
Challa, A ;
Gourtsoyiannis, N .
EUROPEAN RADIOLOGY, 2000, 10 (06) :909-913
[8]   Small bowel MRI using water as a contrast medium [J].
Lomas, DJ ;
Graves, MJ .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (862) :994-997
[9]   MR imaging of the gastrointestinal tract with IV gadolinium and diluted barium oral contrast media compared with unenhanced MR imaging and CT [J].
Low, RN ;
Francis, IR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) :1051-1059
[10]  
Low RN, 2000, JMRI-J MAGN RESON IM, V11, P127, DOI 10.1002/(SICI)1522-2586(200002)11:2<127::AID-JMRI8>3.0.CO