Feasibility of the Inoue single-branched stent-graft implantation for thoracic aortic aneurysm or dissection involving the left subclavian artery: Short- to medium-term results in 17 patients

被引:72
作者
Saito, N
Kimura, T
Odashiro, K
Toma, M
Nobuyoshi, M
Ueno, K
Kita, T
Inoue, K
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[3] Takeda Hosp, Dept Radiol, Kyoto, Japan
[4] Takeda Hosp, Dept Cardiovasc Surg, Kyoto, Japan
关键词
D O I
10.1016/j.jvs.2004.11.030
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study assessed the short- to medium-term clinical results of the Inoue single-branched stent graft for repair of thoracic aortic aneurysms or dissections involving the left subclavian artery. Methods. A retrospective review of experiences at two institutions was performed. We analyzed the data of consecutive 17 patients with thoracic aortic aneurysms or dissections who underwent endovascular repairs with the Inoue singlebranched stent graft between July 1999 and April 2004. Complete baseline and follow-up data were available on all patients. The mean age was 71 9 years, and 13 of the patients (76%) were men. Eight patients (47%) were considered unfit for open surgery because of advanced age or the presence of comorbid diseases. Results. The stent grafts were successfully delivered and deployed in all 17 patients. Periprocedural major complications, defined as those that caused any persistent disorder, occurred in one patient who developed spinal ischernia. A postoperative computed tornographic scan revealed three attachment site endoleaks; two endoleaks were from the proximal attachment sites and one endoleak was from the distal attachment site. The mean follow-up period was 26 months (range, 7 to 65 months). Two deaths occurred in the follow-up period from cerebral bleeding and pneumonia, both considered unrelated to the stent grafting. Two patients with attachment site endoleaks needed secondary stent-grafting; one patient required the implantation of a straight stent-graft in the distal attachment site and the other, the implantation of a double-branched stent-graft. Another patient with attachment site endoleak was considered very high-risk for open surgery or secondary stent grafting and did not undergo secondary intervention. The aneurysmal sac size of the patient has been stable for 28 months. The branched section of the stent graft was patent in all patients in the follow-up period. Conclusion: The results demonstrate the feasibility of the Inoue single-branched stent graft for thoracic aortic aneurysms or dissections involving the left subclavian artery.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 19 条
[1]   Endovascular repair of thoracic aortic aneurysms: Stent-graft fixation across the aortic arch vessels [J].
Burks, JA ;
Faries, PL ;
Gravereaux, EC ;
Hollier, LH ;
Marin, ML .
ANNALS OF VASCULAR SURGERY, 2002, 16 (01) :24-28
[2]   Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection [J].
Chuter, TAM ;
Schneider, DB ;
Reilly, LM ;
Lobo, EP ;
Messina, LM .
JOURNAL OF VASCULAR SURGERY, 2003, 38 (04) :859-863
[3]   Endovascular stent-graft placement for the treatment of acute aortic dissection [J].
Dake, MD ;
Kato, N ;
Mitchell, RS ;
Semba, CP ;
Razavi, MK ;
Shimono, T ;
Hirano, T ;
Takeda, K ;
Yada, I ;
Miller, DC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) :1546-1552
[4]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[5]  
Görich J, 2002, J ENDOVASC THER, V9, P39
[6]   Thoracic aortic aneurysms:: Treatment with endovascular self-expandable stent grafts [J].
Grabenwöger, M ;
Hutschala, D ;
Ehrlich, MP ;
Cartes-Zumelzu, F ;
Thurnher, S ;
Lammer, J ;
Wolner, E ;
Havel, M .
ANNALS OF THORACIC SURGERY, 2000, 69 (02) :441-445
[7]  
Hausegger KA, 2001, J ENDOVASC THER, V8, P472, DOI 10.1583/1545-1550(2001)008<0472:ILSAOB>2.0.CO
[8]  
2
[9]   Endovascular stent-grafting for descending thoracic aortic aneurysm [J].
Heijmen, RH ;
Deblier, IG ;
Moll, FL ;
Dossche, KM ;
van den Berg, JC ;
Overtoom, TT ;
Ernst, SM ;
Schepens, MA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (01) :5-9
[10]   A system for computer-assisted design of stent-grafts for aortic aneurysms using 3-D morphological models [J].
Imai, Y ;
Urayama, S ;
Uyama, C ;
Inoue, K ;
Ueno, K ;
Kuribayashi, S ;
Takamiya, M ;
Hamada, S ;
Hirane, Y .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (04) :277-279