Assessment of uncertainty of NO2 measurements by the chemiluminescence method and discussion of the quality objective of the NO2 European Directive

被引:51
作者
Gerboles, M [1 ]
Lagler, F
Rembges, D
Brun, C
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Environm & Sustainabil, I-21020 Ispra, Italy
[2] Commiss European Communities, Joint Res Ctr, Inst Hlth & Consumer Protect, I-21020 Ispra, Italy
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2003年 / 5卷 / 04期
关键词
D O I
10.1039/b302358c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hereafter, an assessment of the ability of the chemiluminescence method to measure ambient NO, with an accuracy within 15%, as requested by the data quality objective of European directive 1999/30/CE, is presented. In general, uncertainty is evaluated using the response to reference materials or by means of inter-comparisons used to determine some statistics like repeatability, reproducibility and calibration bias. These are incomplete approaches and the method of the Guide to the Expression of Uncertainty in Measurement, advised by the Directive, should be preferred. In fact, even if it requires a large data set, it allows the relative influence of all possible sources of uncertainty to be studied. The extent of NO2 uncertainty is mainly dependent on the level of NO. It is decreased by NOx and the correlation between NOx and NO. Furthermore, the uncertainty budget reveals that the contribution of accuracy of calibration standard, linearity, converter efficiency and drift of the analyser between calibration checks to the overall uncertainty is less important than the contribution of interference, mainly humidity and PAN in rural areas. The relative expanded uncertainty or the NO2 hourly average exceeds 30% for NO2 concentrations lower than 40 mug m(-3). Nevertheless, the data quality objective of 3 15% is reached for 200 mug m(-3), the hourly limit value of the European directive. On the contrary, at the limit value on the annual average, 40 mug m(-3), the data quality objective is not met if NO is higher than 100 mug m(-3). However, the data quality objective could be reached by correcting the measurements with the bias due to interference.
引用
收藏
页码:529 / 540
页数:12
相关论文
共 24 条
[1]  
*COM EUR NORM, 2002, 14377 CR COM EUR NOR
[2]  
*COM EUR NORM, 2003, 14211 PREN CEN
[3]  
*EIG UMW BUND, 1993, 17 THERM INSTR SYST
[4]   Uncertainty calculation and implementation of the static volumetric method for the preparation of NO and SO2 standard gas mixtures [J].
Gerboles, M ;
Diaz, E ;
Noriega-Guerra, A .
ACCREDITATION AND QUALITY ASSURANCE, 1998, 3 (02) :69-78
[5]  
GERBOLES M, 2002, 20381EN EUR
[6]  
GERBOLES M, 2001, INT C MEAS AIR POLL
[7]   RESPONSE OF CHEMI-LUMINESCENCE NOX ANALYZERS AND ULTRAVIOLET OZONE ANALYZERS TO ORGANIC AIR-POLLUTANTS [J].
GROSJEAN, D ;
HARRISON, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1985, 19 (09) :862-865
[8]  
*INT STAND ORG, 1998, 137521998E ISO
[9]  
*INT STAND ORG, 1998, 6145102002E ISO
[10]  
*INT STAND ORG, 2001, 61432001E ISO