Biomechanical comparisons of three posterior cruciate ligament reconstruction procedures with load-controlled and displacement-controlled cyclic tests

被引:12
作者
Kitamura, N
Yasuda, K
Yamanaka, M
Tohyama, H
机构
[1] Hokkaido Univ, Sch Med, Dept Med Bioengn & Sports Med, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Sch Med, Dept Sports Med & Joint Recontruct Surg, Sapporo, Hokkaido 0608638, Japan
关键词
D O I
10.1177/03635465030310062801
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Biomechanical behaviors of posterior cruciate ligament reconstructions under cyclic loading have not been sufficiently clarified. Hypothesis: Biomechanical behaviors of the reconstruction that involves use of flexor tendons and an Endobutton are significantly different under cyclic loading from behaviors of the two standard reconstructions in which bone-patellar tendon-bone graft is used. Study Design: Controlled laboratory study. Methods: In a porcine model, the tendon/Endobutton reconstruction, the tendon-bone/interference screw reconstruction, and the tendon-bone/tibial-inlay reconstruction were biomechanically compared by using two cyclic tests. In each group of 15 specimens, 5 knees underwent tensile testing without cyclic loading, and the remaining 10 underwent the same tensile test after 5000 cycles of load-controlled or displacement-controlled loading. Results: At the 5000th cycle, the peak displacement or the peak load was affected by each type of cyclic loading to a significantly greater degree in the knees with the tendon/Endobutton procedure than in the knees reconstructed with the other two procedures. Conclusions: Plastic deformation occurred more easily during cyclic loading in the knees with the tendon/Endobutton reconstruction than in the knees with the tendon-bone reconstructions. Clinical Relevance: When the tendon/Endobutton reconstruction is used, a longer period of postoperative immobilization is necessary. (C) 2003 American Orthopaedic Society for Sports Medicine.
引用
收藏
页码:907 / 914
页数:8
相关论文
共 26 条
[1]
POSTERIOR CRUCIATE LIGAMENT TIBIAL INLAY RECONSTRUCTION [J].
BERG, EE .
ARTHROSCOPY, 1995, 11 (01) :69-76
[2]
A biomechanical comparison of posterior cruciate ligament reconstruction techniques [J].
Bergfeld, JA ;
McAllister, DR ;
Parker, RD ;
Valdevit, ADC ;
Kambic, HE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) :129-136
[3]
Bomberg B., 1990, AM J KNEE SURG, V3, P85
[4]
Brown G A, 1996, Knee Surg Sports Traumatol Arthrosc, V3, P238, DOI 10.1007/BF01466626
[5]
Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure [J].
Burkhart, SS ;
Johnson, TC ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (02) :172-176
[6]
THE EFFECT OF FEMORAL TUNNEL POSITION AND GRAFT TENSIONING TECHNIQUE ON POSTERIOR LAXITY OF THE POSTERIOR CRUCIATE LIGAMENT-RECONSTRUCTED KNEE [J].
BURNS, WC ;
DRAGANICH, LF ;
PYEVICH, M ;
REIDER, B .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (04) :424-430
[7]
Testing for isometry during reconstruction of the posterior cruciate ligament - Anatomic and biomechanical considerations [J].
Covey, DC ;
Sapega, AA ;
Sherman, GM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (06) :740-746
[8]
ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH PATELLAR TENDON - AN EX-VIVO STUDY OF WEAR-RELATED DAMAGE AND FAILURE AT THE FEMORAL TUNNEL [J].
GRAF, BK ;
HENRY, J ;
ROTHENBERG, M ;
VANDERBY, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (01) :131-135
[9]
FACTORS AFFECTING THE REGION OF MOST ISOMETRIC FEMORAL ATTACHMENTS .1. THE POSTERIOR CRUCIATE LIGAMENT [J].
GROOD, ES ;
HEFZY, MS ;
LINDENFIELD, TN .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (02) :197-207
[10]
JAKOB RP, 1993, ORTHOPADE, V22, P405