Respiratory deposition patterns of salbutamol pMDI with CFC and HFA-134a formulations in a human airway replica

被引:84
作者
Cheng, YS [1 ]
Fu, CS [1 ]
Yazzie, D [1 ]
Zhou, Y [1 ]
机构
[1] Lovelace Resp Res Inst, Albuquerque, NM 87185 USA
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2001年 / 14卷 / 02期
关键词
lung; inhalation; HFA-134a; pMDI; drug delivery; deposition;
D O I
10.1089/08942680152484180
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This paper describes a technique that uses a well-defined human airway replica and gamma counting as a standard method for evaluating and comparing the performance of medical inhalers and spacers. High-fidelity replicas reproduced as needed from master casts made from human cadavers include the oropharyngeal cavity, larynx, trachea, and five to nine generations of bronchi. Deposition in the small airways and alveoli region of the cast is simulated by material that passes through the upstream airways and is collected on foam filters. Deposition patterns in the respiratory tract replica were obtained by using radiolabel in the medical inhaler and by gamma scintigraphy. This technique was used to determine respiratory deposition patterns of salbutamol in a pressurized metered dose inhaler (pMDI) with chlorofluorocarbon (CFC, in-house formulation) and HFA-134 formulations (Proventil hydrofluoroalkane [HFA]). At an inspiration flow of 30 L/min, patterns in the salbutamol/CFC formula showed a high deposition in the oropharyngeal airway (78%) and a 16% deposition in the lung, similar to in vivo measurements reported in the literature. However, the salbutamol/HFA formula showed lower oral deposition (56%) but higher lung deposition (24%). The difference in the oral deposition patterns may be attributed to lower initial spray velocity, initial droplet evaporation rate, and possibly initial droplet sizes of Proventil HFA. The small orifice diameter (0.25 mm) of the Proventil HFA actuator produced a softer plume with a smaller impact force, resulting in lower oropharyngeal deposition. Cascade impactor measurements showed similar aerodynamic particle size distribution of the CFC and HFA formulations. We also showed that using spacers in the Proventil HFA resulted in a lower oropharyngeal. deposition and higher lung deposition, indicating beneficial effects. Comparison of oropharyngeal deposition and those predicted by artificial throats used in the impactor measurements showed that, in general, the artificial throat predicted a lower deposition.
引用
收藏
页码:255 / 266
页数:12
相关论文
共 33 条
[1]   In vitro comparison of the amount of salbutamol available for inhalation from different formulations used with different spacer devices [J].
Barry, PW ;
OCallaghan, C .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (06) :1345-1348
[2]   DEPOSITION OF INHALED PARTICLES IN THE ORAL AIRWAY DURING ORONASAL BREATHING [J].
BOWES, SM ;
SWIFT, DL .
AEROSOL SCIENCE AND TECHNOLOGY, 1989, 11 (02) :157-167
[3]   EXPERIMENTAL MEASUREMENTS AND EMPIRICAL MODELING OF THE REGIONAL DEPOSITION OF INHALED PARTICLES IN HUMANS [J].
CHAN, TL ;
LIPPMANN, M .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (06) :399-408
[4]  
Cheng KH, 1997, AM IND HYG ASSOC J, V58, P207, DOI 10.1202/0002-8894(1997)058<0207:AEMFMA>2.0.CO
[5]  
2
[6]   Particle deposition in a cast of human oral airways [J].
Cheng, YS ;
Zhou, Y ;
Chen, BT .
AEROSOL SCIENCE AND TECHNOLOGY, 1999, 31 (04) :286-300
[7]   DEPOSITION OF ULTRAFINE PARTICLES IN THE UPPER AIRWAYS - AN EMPIRICAL-ANALYSIS [J].
COHEN, BS ;
ASGHARIAN, B .
JOURNAL OF AEROSOL SCIENCE, 1990, 21 (06) :789-797
[8]   Deposition of charged particles on lung airways [J].
Cohen, BS ;
Xiong, JQ ;
Fang, CP ;
Li, W .
HEALTH PHYSICS, 1998, 74 (05) :554-560
[9]   MEASUREMENTS OF THE TOTAL AND REGIONAL DEPOSITION OF INHALED PARTICLES IN THE HUMAN RESPIRATORY-TRACT [J].
EMMETT, PC ;
AITKEN, RJ ;
HANNAN, WJ .
JOURNAL OF AEROSOL SCIENCE, 1982, 13 (06) :549-560
[10]   AEROSOL DEPOSITION IN THE HUMAN LUNG FOLLOWING ADMINISTRATION FROM A MICROPROCESSOR-CONTROLLED PRESSURIZED METERED-DOSE INHALER [J].
FARR, SJ ;
ROWE, AM ;
RUBSAMEN, R ;
TAYLOR, G .
THORAX, 1995, 50 (06) :639-644