Experimental determination of reactive oxygen species in Taipei aerosols

被引:105
作者
Hung, HF
Wang, CS
机构
[1] Natl Taiwan Univ, Grad Inst Environm Hlth, Taipei 10764, Taiwan
[2] Natl Taiwan Univ, Dept Publ Hlth, Taipei 10764, Taiwan
[3] Natl Taiwan Univ, Grad Inst Occupat Med & Ind Hyg, Taipei 10764, Taiwan
关键词
urban aerosol; fine particles; fresh aerosol; aged aerosol;
D O I
10.1016/S0021-8502(01)00051-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The concentrations of reactive oxygen species (ROS) in various particle size fractions were determined for the Taipei aerosols and for particles in vehicular exhausts. Sampling of particles was carried out at a sidewalk and an underpass by a cascade impactor. The sampling duration was 3 h during daytime at the sidewalk and 20-30 min during rush hours in the underpass. The collected particles were treated with a non-fluorescent probe dichlorofluorescin (DCFH2) that forms highly fluorescent dichlorofluorescin (DCF) when oxidized in the presence of ROS. Data on the fluorescence intensity of DCF were converted into equivalent hydrogen peroxide concentrations using calibration curves obtained from H2O2 assay. The equivalent H2O2 concentration was used as an indicator for the reactivity of ROS in particles. The concentration of ROS in ambient particles had good correlations with the intensity of photochemical reactions. The correlation coefficient between the ROS concentration and the O-3 concentration was higher for smaller particles. This indicates that the intensity of photochemical reactions is a major factor affecting ROS concentration in smaller particles, especially in ultrafine particles (aerodynamic diameter <0.18 mum). Moreover, for the same mass concentrations of particles, the content of ROS was found to be higher in smaller particles, except for ultrafine particles. This pattern was observed only in the particles sampled at the sidewalk, and not those in the underpass. The results suggest that, for the same particle mass concentration, smaller particles in ambient aerosols have higher ROS contents and, therefore, may have a greater potential to cause damage to the pulmonary cells. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1201 / 1211
页数:11
相关论文
共 18 条
[1]   Freshly generated stainless steel welding fume induces greater lung inflammation in rats as compared to aged fume [J].
Antonini, JM ;
Clarke, RW ;
Murthy, GGK ;
Sreekanthan, P ;
Jenkins, N ;
Eagar, TW ;
Brain, JD .
TOXICOLOGY LETTERS, 1998, 98 (1-2) :77-86
[2]   SPECTROFLUOROMETRIC ANALYSIS OF HYDROGEN-PEROXIDE [J].
BLACK, MJ ;
BRANDT, RB .
ANALYTICAL BIOCHEMISTRY, 1974, 58 (01) :246-254
[3]   DETECTION OF PICOMOLE LEVELS OF HYDROPEROXIDES USING A FLUORESCENT DICHLOROFLUORESCEIN ASSAY [J].
CATHCART, R ;
SCHWIERS, E ;
AMES, BN .
ANALYTICAL BIOCHEMISTRY, 1983, 134 (01) :111-116
[4]  
Friedlander S.K., 1998, APPL OCCUP ENV HYG, V13, P416, DOI DOI 10.1080/1047322X.1998.10389566
[5]   DETECTION OF METHYL, HYDROXYMETHYL AND HYDROXYETHYL HYDROPEROXIDES IN AIR AND PRECIPITATION [J].
HELLPOINTNER, E ;
GAB, S .
NATURE, 1989, 337 (6208) :631-634
[6]   FREE-RADICALS AS MEDIATORS OF TISSUE-INJURY AND DISEASE [J].
KEHRER, JP .
CRITICAL REVIEWS IN TOXICOLOGY, 1993, 23 (01) :21-48
[7]   Involvement of oxidative stress in motorcycle exhaust particle-induced DNA damage and inhibition of intercellular communication [J].
Kuo, ML ;
Jee, SH ;
Chou, MH ;
Ueng, TH .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 1998, 413 (02) :143-150
[8]   EVALUATION OF THE PROBE 2',7'-DICHLOROFLUORESCIN AS AN INDICATOR OF REACTIVE OXYGEN SPECIES FORMATION AND OXIDATIVE STRESS [J].
LEBEL, CP ;
ISCHIROPOULOS, H ;
BONDY, SC .
CHEMICAL RESEARCH IN TOXICOLOGY, 1992, 5 (02) :227-231
[9]   GAS-PHASE, CLOUD AND RAIN-WATER MEASUREMENTS OF HYDROGEN-PEROXIDE AT A HIGH-ELEVATION SITE [J].
OLSZYNA, KJ ;
MEAGHER, JF ;
BAILEY, EM .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (08) :1699-1706
[10]  
PRYOR WA, 1992, FREE RADICAL BIO MED, V13, P659