Mass analysis of water-soluble polymers by mobility measurement of charge-reduced ions generated by electrosprays

被引:54
作者
Saucy, DA
Ude, S
Lenggoro, IW
de la Mora, JF
机构
[1] Rohm & Haas Co, Spring House, PA 19477 USA
[2] Yale Univ, Dept Chem, New Haven, CT 06520 USA
[3] Yale Univ, Dept Mech Engn, New Haven, CT 06520 USA
[4] Hiroshima Univ, Grad Sch Engn, Dept Chem Engn, Higashihiroshima, Hiroshima 7398527, Japan
关键词
D O I
10.1021/ac034138m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aqueous solutions of poly(ethylene glycol) (PEG) in a 10 mM ammonium acetate buffer are electrosprayed, and the maximum charge state on the resulting gas-phase ions is reduced to unity using a radioactive source. The mobility distribution of these charged particles is then measured in air in a differential mobility analyzer of unusually high resolution. The relation Z(m) between the mobility Z of a polymer molecule and its mass m is determined by means of narrowly distributed PEG mass standards. The molecular weight range of available standards is extended by generating clusters containing from one up to six molecules of the primary PEG standard. The mass at the peak of the distribution of the lowest standard (PEG-4k) is determined by MALDI mass spectrometry and agrees with the manufacturer's value and previous MALDI literature data. The masses for the 50K and 120K standards are found to differ by 8.6 and 6.6%, respectively, from the manufacturer's value. Using known relationships, the particle diameter d of the ions is calculated from the measured mobility. Plots of d versus m(1/3) give Straight lines over the full mass range studied (4000-700 000 Da, particle diameter from 3 to 12 nm), indicating that these PEG particles are indeed spherical and have a density rho independent of size. The slope of the d versus m(1/3) curve provides a density rho = 1.25 g/cm(3), close to the known bulk density, rho(PEG) = 1.21 g/cm(3).
引用
收藏
页码:1045 / 1053
页数:9
相关论文
共 43 条
[1]  
*ALDR CHEM CO INC, 1994, ALDR CAT HDB FIN CHE, P1162
[2]   Charge-reduced nano electrospray ionization combined with differential mobility analysis of peptides, proteins, glycoproteins, noncovalent protein complexes and viruses [J].
Bacher, G ;
Szymanski, WW ;
Kaufman, SL ;
Zöllner, P ;
Blaas, D ;
Allmaier, G .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (09) :1038-1052
[3]   MASS-SPECTROMETRY OF SYNTHETIC-POLYMERS BY UV MATRIX-ASSISTED LASER DESORPTION IONIZATION [J].
BAHR, U ;
DEPPE, A ;
KARAS, M ;
HILLENKAMP, F ;
GIESSMANN, U .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2866-2869
[4]   Flow field-flow fractionation of poly(ethylene oxide): effect of carrier ionic strength and composition [J].
Benincasa, MA ;
Caldwell, KD .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :159-169
[5]   The limitations of MALDI-TOF mass spectrometry in the analysis of wide polydisperse polymers [J].
Byrd, HCM ;
McEwen, CN .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4568-4576
[6]   High resolution size analysis of nanoparticles and ions: Running a Vienna DMA of near optimal length at Reynolds numbers up to 5000 [J].
de Juan, L ;
de la Mora, JF .
JOURNAL OF AEROSOL SCIENCE, 1998, 29 (5-6) :617-626
[7]  
de la Mora JF, 2000, ANAL CHIM ACTA, V406, P93
[8]   Differential mobility analysis of molecular ions and nanometer particles [J].
de la Mora, JF ;
de Juan, L ;
Eichler, T ;
Rosell, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (06) :328-339
[9]  
EICHLER T, 1997, THESIS
[10]  
Fenn JB, 1996, ACS SYM SER, V619, P60