Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible

被引:349
作者
Hermann, JS
Schoolfield, JD
Schenk, RK
Buser, D
Cochran, DL [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, Sch Dent, Dept Periodont, San Antonio, TX 78284 USA
[2] Univ Zurich, Sch Dent, Dept Prevent Dent Periodont & Cariol, Zurich, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Oral Surg, Bern, Switzerland
关键词
alveolar bone/anatomy and histology; animal studies; dental implants; endosseous/methods; tooth movement; titanium; dental implants/anatomy and histology; follow-up studies;
D O I
10.1902/jop.2001.72.10.1372
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Endosseous implants can be placed according to a non-submerged or submerged approach and in 1- or 2-piece configurations. Recently, it was shown that peri-implant crestal bone changes differ significantly under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of an interface (microgap) between the implant and abutment/restoration in 2-piece configurations. Several factors may influence the resultant level of the crestal bone under these conditions, including movements between implant components and the size of the microgap (interface) between the implant and abutment. However, no data are available on the impact of possible movements between these components or the impact of the size of the microgap (interface). The purpose of this study was to histometrically evaluate crestal bone changes around unloaded, 2-piece non-submerged titanium implants with 3 different microgap (interface) dimensions and between implants with components welded together or held together by a transocclusal screw. Methods: A total of 60 titanium implants were randomly placed in edentulous mandibular areas of 5 hounds forming 6 different implant subgroups (A through F). In general, all implants had a relatively smooth, machined suprabony portion 1 mm long, as well as a rough, sandblasted, and acid-etched (SLA) endosseous portion, all placed with their interface (microgap) 1 mm above the bone crest level and having abutments connected at the time of first-stage surgery. Implant types A, B, and C had a microgap of < 10 mum, similar to 50 mum, or similar to 100 mum between implant components as did types D, E, and F, respectively. As a major difference, however, abutments and implants of types A, B, and C were laser-welded together, not allowing for any movements between components, as opposed to types D, E, and F, where abutments and implants were held together by abutment screws. Three months after implant placement, all animals were sacrificed. Non-decalcified histology was analyzed histometrically by evaluating peri-implant crestal bone changes. Results: For implants in the laser-welded group (A, B, and C), mean crestal bone levels were located at a distance from the interface (IF; microgap) to the first bone-to-implant contact (fBIC) of 1.06 +/- 0.46 mm (standard deviation) for type A, 1.28 +/- 0.47 mm for type B, and 1.17 +/- 0.51 mm for type C. All implants of the non-welded group (D, E, and F) had significantly increased amounts of crestal bone loss, with 1.72 +/- 0.49 mm for type D (P <0.01 compared to type A), 1.71 +/- 0.43 mm for type E (P <0.02 compared to type B), and 1.65 +/- 0.37 mm for type F (P <0.01 compared to type C). Conclusions: These findings demonstrate, as evaluated by non-decalcified histology under unloaded conditions in the canine mandible, that crestal bone changes around 2-piece, non-submerged titanium implants are significantly influenced by possible movements between implants and abutments, but not by the size of the microgap (interface). Thus, significant crestal bone loss occurs in 2-piece implant configurations even with the smallest-sized microgaps (< 10 mum) in combination with possible movements between implant components.
引用
收藏
页码:1372 / 1383
页数:12
相关论文
共 39 条
[1]   The peri-implant hard and soft tissues at different implant systems - A comparative study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Wennstrom, J ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :212-219
[2]   Peri-implant tissues at submerged and non-submerged titanium implants [J].
Abrahamsson, I ;
Berglundh, T ;
Moon, IS ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1999, 26 (09) :600-607
[3]   The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[4]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[5]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[6]  
Becker W, 1997, INT J ORAL MAX IMPL, V12, P454
[7]   The soft tissue barrier at implants and teeth [J].
Berglundh, T. ;
Lindhe, J. ;
Ericsson, I. ;
Marinello, C. P. ;
Liljenberg, B. ;
Thomsen, P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1991, 2 (02) :81-90
[8]   OSSEOINTEGRATION OF BRANEMARK FIXTURES USING A SINGLE-STEP OPERATING TECHNIQUE - A PRELIMINARY PROSPECTIVE ONE-YEAR STUDY IN THE EDENTULOUS MANDIBLE [J].
BERNARD, JP ;
BELSER, UC ;
MARTINET, JP ;
BORGIS, SA .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (02) :122-129
[9]  
BESIMO C, 1994, Z ZAHNARZTL IMPLANTO, V10, P191
[10]  
BINON P, 1992, TISSUE INTEGRATION O, V1, P218