An initial application of transesophageal Doppler echocardiography in experimental small animal models

被引:12
作者
Gao, ZH [1 ]
Li, JH [1 ]
Kehoe, V [1 ]
Davidson, WR [1 ]
Sinoway, L [1 ]
Pu, M [1 ]
机构
[1] Penn State Univ, Milton S Hershey Med Ctr, Div Cardiol, Coll Med, Hershey, PA 17033 USA
关键词
D O I
10.1016/j.echo.2004.08.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study examined whether an intracardiac echocardiography catheter could be used for transesophageal echocardiography (TEE) examinations in normal rats, and intraoperative TEE in small animal models of disease. The study used 30 Sprague-Dawley normal rats, 10 rats undergoing coronary artery ligation, and 10 rats with experimentally induced mitral regurgitation. The rats were anesthetized with isoflurane and intubated. An intracardiac echocardiographic catheter was inserted into the esophagus. M-mode, 2-dimensional, and Doppler studies were performed in multiple views. TEE probe insertions were successful in all animals. Intraoperative TEE was safely performed in the rat models of myocardial infarction or mitral regurgitation. Mitral regurgitation was well assessed using color Doppler and pulmonary venous flow. This study demonstrates that TEE (including intraoperative TEE) can be safely performed in rats using an intracardiac echocardiographic catheter. It provides a new approach to the assessment of cardiac function and valvular regurgitation in small animals.
引用
收藏
页码:626 / 631
页数:6
相关论文
共 36 条
[1]   ESTIMATION OF LEFT-VENTRICULAR FILLING PRESSURES USING 2-DIMENSIONAL AND DOPPLER-ECHOCARDIOGRAPHY IN ADULT PATIENTS WITH CARDIAC DISEASE - ADDITIONAL VALUE OF ANALYZING LEFT ATRIAL SIZE, LEFT ATRIAL EJECTION FRACTION AND THE DIFFERENCE IN DURATION OF PULMONARY VENOUS AND MITRAL FLOW VELOCITY AT ATRIAL CONTRACTION [J].
APPLETON, CP ;
GALLOWAY, JM ;
GONZALEZ, MS ;
GABALLA, M ;
BASNIGHT, MA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) :1972-1982
[2]   Feasibility study: Transesophageal echocardiography with a 10F (3.2-mm), multifrequency (5.5-to 10-MHz) ultrasound catheter in a small rabbit model [J].
Bruce, CJ ;
Packer, DL ;
O'Leary, PW ;
Seward, JB .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (07) :596-600
[3]   EFFECT OF MITRAL REGURGITATION ON PULMONARY VENOUS VELOCITIES DERIVED FROM TRANSESOPHAGEAL ECHOCARDIOGRAPHY COLOR-GUIDED PULSED DOPPLER IMAGING [J].
CASTELLO, R ;
PEARSON, AC ;
LENZEN, P ;
LABOVITZ, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (07) :1499-1506
[4]   Real time quantification of low temperature radiofrequency ablation lesion size using phased array intracardiac echocardiography in the canine model: comparison of two dimensional images with pathological lesion characteristics [J].
Doi, A ;
Takagi, M ;
Toda, I ;
Teragaki, M ;
Yoshiyama, M ;
Takeuchi, K ;
Yoshikawa, J .
HEART, 2003, 89 (08) :923-927
[5]   Cardiac morphology and function in senescent rats: Gender-related differences [J].
Forman, DE ;
Cittadini, A ;
Azhar, G ;
Douglas, PS ;
Wei, JY .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1872-1877
[6]  
FREMAN WK, 1994, TRANSESOPHAGEAL ECHO
[7]   Intravascular ultrasound catheter evaluation of the left ventricle in mice: A feasibility study [J].
Gardin, JM ;
Siri, F ;
Kitsis, RN ;
Leinwand, L .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (06) :609-612
[8]   ECHOCARDIOGRAPHIC CHARACTERIZATION OF LEFT-VENTRICULAR ADAPTATION IN A GENETICALLY-DETERMINED HEART-FAILURE RAT MODEL [J].
HASS, GJ ;
MCCUNE, SA ;
BROWN, DM ;
CODY, RJ .
AMERICAN HEART JOURNAL, 1995, 130 (04) :806-811
[9]   INFLUENCE OF LOADING CONDITIONS AND CONTRACTILE STATE ON PULMONARY VENOUS FLOW - VALIDATION OF DOPPLER VELOCIMETRY [J].
HOIT, BD ;
SHAO, YF ;
GABEL, M ;
WALSH, RA .
CIRCULATION, 1992, 86 (02) :651-659
[10]  
Kamp O, 1992, J Am Soc Echocardiogr, V5, P239