A large-scale low-background liquid scintillation detector: the counting test facility at Gran Sasso

被引:144
作者
Alimonti, G
Arpesella, C
Bacchiocchi, G
Balata, M
Bellini, G
Benziger, J [1 ]
Bonetti, S
Brigatti, A
Cadonati, L
Calaprice, FP
Cavaletti, R
Cecchet, G
Chen, M
Darnton, N
deBari, A
Deutsch, M
Elisei, F
von Feilitzsch, F
Galbiati, C
Garagiola, A
Gatti, F
Giammarchi, MG
Giugni, D
Goldbrunner, T
Golubchikov, A
Goretti, A
Grabar, S
Hagner, T
Hartmann, F
von Hentig, R
Heusser, G
Ianni, A
Jochum, J
Johnson, M
Laubenstein, M
Loeser, F
Lombardi, P
Magni, S
Malvezzi, S
Manno, I
Manuzio, G
Masetti, F
Mazzucato, U
Meroni, E
Neff, M
Nisi, S
Nostro, A
Oberauer, L
Perotti, A
Preda, A
机构
[1] Princeton Univ, Sch Engn, Princeton, NJ 08544 USA
[2] Univ Milan, Dept Phys, Milan, Italy
[3] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[4] Tech Univ Munich, D-8046 Garching, Germany
[5] Lab Nazl Gran Sasso, Assergi, AQ, Italy
[6] Princeton Univ, Dept Phys, Princeton, NJ 08544 USA
[7] Univ Pavia, Dept Phys, I-27100 Pavia, Italy
[8] Ist Nazl Fis Nucl, I-27100 Pavia, Italy
[9] MIT, Cambridge, MA 02139 USA
[10] Univ Perugia, Dept Phys, I-06100 Perugia, Italy
[11] Ist Nazl Fis Nucl, I-06100 Perugia, Italy
[12] Univ Genoa, Dept Phys, Genoa, Italy
[13] Ist Nazl Fis Nucl, I-16146 Genoa, Italy
[14] Joint Inst Nucl Res, Dubna, Russia
[15] Max Planck Inst, Heidelberg, Germany
[16] Lucent Technol, Murray Hill, NJ USA
关键词
D O I
10.1016/S0168-9002(98)00018-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A 4.8 m(3) unsegmented liquid scintillation detector at the underground Laboratori Nazionali del Gran Sasso has shown the feasibility of multi-ton low-background detectors operating to energies as low as 250 keV. Detector construction and the handling of large volumes of liquid scintillator to minimize the background are described. The scintillator, 1.5 g PPO/L-pseudocumene, is held in a flexible nylon vessel shielded by 1000 t of purified water. The active detector volume is viewed by 100 photomultipliers, which measure time and charge for each event, from which energy, position and pulse shape are deduced. On-line purification of the scintillator by water extraction, vacuum distillation and nitrogen stripping removed radioactive impurities. Upper limits were established of < 10(-7) Bq/kg-scintillator for events with energies 250 keV < E < 800 keV, and < 10(-9) Bq/g-scintillator due to the decay products of uranium and thorium. The isotopic abundance of C-14/C-12 in the scintillator was shown to be approximately 10(-18) by extending the energy window of the detector to 25-250 keV. The C-14 abundance and uranium and thorium levels in the CTF are compatible with the Borexino Solar Neutrino Experiment. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:411 / 426
页数:16
相关论文
共 39 条
[1]   A HEAVY-WATER DETECTOR TO RESOLVE THE SOLAR NEUTRINO PROBLEM [J].
AARDSMA, G ;
ALLEN, RC ;
ANGLIN, JD ;
BERCOVITCH, M ;
CARTER, AL ;
CHEN, HH ;
DAVIDSON, WF ;
DOE, PJ ;
EARLE, ED ;
EVANS, HC ;
EWAN, GT ;
HALLMAN, ED ;
HARGROVE, CK ;
JAGAM, P ;
KESSLER, D ;
LEE, HW ;
LESLIE, JR ;
MACARTHUR, JD ;
MAK, HB ;
MCDONALD, AB ;
MCLATCHIE, W ;
ROBERTSON, BC ;
SIMPSON, JJ ;
SINCLAIR, D ;
SKENSVED, P ;
STOREY, RS .
PHYSICS LETTERS B, 1987, 194 (02) :321-325
[2]   The muon induced background in the GALLEX experiment [J].
Cribier, M ;
Pichard, B ;
Rich, J ;
Soirat, JP ;
Spiro, M ;
Stolarczyk, T ;
Tao, C ;
Vignaud, D ;
Anselmann, P ;
Lenzing, A ;
Schlosser, C ;
Wink, R ;
Rowley, JK .
ASTROPARTICLE PHYSICS, 1997, 6 (02) :129-141
[3]  
[Anonymous], 1964, THEORY PRACTICE SCIN
[4]  
Bahcall J.N., 1989, Neutrino Astrophysics
[5]   Solar neutrinos: Where we are, where we are going [J].
Bahcall, JN .
ASTROPHYSICAL JOURNAL, 1996, 467 (02) :475-484
[6]   The water purification system for the low background counting test facility of the Borexino experiment at Gran Sasso [J].
Balata, M ;
Cadonati, L ;
Laubenstein, M ;
Heusser, G ;
Giammarchi, MG ;
Scardaoni, R ;
Torri, V ;
Cecchet, G ;
deBari, A ;
Perotti, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (2-3) :605-608
[7]   STATUS OF THE SEARCH FOR MATTER STABILITY [J].
BARLOUTAUD, R .
NUCLEAR PHYSICS B, 1992, :437-446
[8]  
BENZIGER JB, UNPUB PURIFICATION S
[9]  
BENZIGER JB, UNPUB FLEXIBLE CONFI
[10]  
BERESNEV VI, 1979, 16TH P INT COSM RAY, V10, P293