Automated high throughput multiple target screening of molecular libraries by microfluidic MALDI-TOF MS

被引:25
作者
Hsieh, F [1 ]
Keshishian, H [1 ]
Muir, C [1 ]
机构
[1] Millenium Pharmaceut Inc, Cambridge, MA 02139 USA
关键词
D O I
10.1177/108705719800300305
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Novel analytical techniques are demanded in parallel in the automated combinatorial library syntheses for accelerating the process of drug discovery. In this study, the integration of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) and robotics for simultaneously identifying lead compounds with activity against multiple enzyme targets has been shown. MALDI-TOF MS monitors the interactions between multienzyme targets and a library of compounds and then identifies individual compounds from molecular libraries that affect the enzymatic activities of multiplexed target molecules to catalyze the conversion of substrates to products, The novel mass spectrometry screening in high-density format (similar to 4,000 samples in a single 4.5 x 4.5 cm MALDI plate) provides much higher throughput over traditional screening approaches in terms of multiplex targets, atto-mole-level sensitivity, very low volume of samples required (10(-9)-10(-12) l), and data acquisition for each sample within ten sec. The microfluidic multiple target screening approach mass spectrometry was shown for discovery of enzyme inhibitors as potential lead compounds.
引用
收藏
页码:189 / 198
页数:10
相关论文
共 24 条
[1]  
BREEMEN RB, 1997, ANAL CHEM, V69, P2159
[2]   Affinity capillary electrophoresis mass spectrometry for screening combinatorial libraries [J].
Chu, YH ;
Dunayevskiy, YM ;
Kirby, DP ;
Vouros, P ;
Karger, BL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (33) :7827-7835
[3]   DESIGN AND SYNTHESES OF POTENT AND SELECTIVE DIPEPTIDE INHIBITORS OF CANDIDA-ALBICANS MYRISTOYL-COA-PROTEIN N-MYRISTOYLTRANSFERASE [J].
DEVADAS, B ;
ZUPEC, ME ;
FREEMAN, SK ;
BROWN, DL ;
NAGARAJAN, S ;
SIKORSKI, JA ;
MCWHERTER, CA ;
GETMAN, DP ;
GORDON, JI .
JOURNAL OF MEDICINAL CHEMISTRY, 1995, 38 (11) :1837-1840
[4]  
Dunayevskiy YM, 1997, RAPID COMMUN MASS SP, V11, P1178, DOI 10.1002/(SICI)1097-0231(199707)11:11<1178::AID-RCM991>3.0.CO
[5]  
2-H
[6]   DETECTION OF NONCOVALENT RECEPTOR LIGAND COMPLEXES BY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (16) :6294-6296
[7]   MASS-SPECTROMETRIC DETECTION OF THE NONCOVALENT GDP-BOUND CONFORMATIONAL STATE OF THE HUMAN H-RAS PROTEIN [J].
GANGULY, AK ;
PRAMANIK, BN ;
TSARBOPOULOS, A ;
COVEY, TR ;
HUANG, E ;
FUHRMAN, SA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (16) :6559-6560
[8]   Screening derivatized peptide libraries for tight binding inhibitors to carbonic anhydrase II by electrospray ionization mass spectrometry [J].
Gao, JM ;
Cheng, XH ;
Chen, RD ;
Sigal, GB ;
Bruce, JE ;
Schwartz, BL ;
Hofstadler, SA ;
Anderson, GA ;
Smith, RD ;
Whitesides, GM .
JOURNAL OF MEDICINAL CHEMISTRY, 1996, 39 (10) :1949-1955
[9]   DIRECT OBSERVATION OF A DNA QUADRUPLEX BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY [J].
GOODLETT, DR ;
CAMP, DG ;
HARDIN, CC ;
CORREGAN, M ;
SMITH, RD .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (03) :181-183
[10]   Multidimensional chromatography coupled with mass spectrometry for target-based screening [J].
Hsieh, YF ;
Gordon, N ;
Regnier, F ;
Afeyan, N ;
Martin, SA ;
Vella, GJ .
MOLECULAR DIVERSITY, 1997, 2 (04) :189-196