RETRACTED: Point-of-care (POC) testing of lactate in the intensive care patient - Accuracy, reliability, and costs of different measurement systems (Retracted article. See vol. 55, pg. 903, 2011)

被引:45
作者
Boldt, J [1 ]
Kumle, B [1 ]
Suttner, S [1 ]
Haisch, G [1 ]
机构
[1] Klinikum Stadt Ludwigshafen, Dept Anesthesiol & Intens Care Med, D-67063 Ludwigshafen, Germany
关键词
critically ill; point-of-care (POC); lactate; accuracy; costs; outcome; hypoperfusion;
D O I
10.1034/j.1399-6576.2001.450210.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Point-of-care (POC) monitoring may facilitate diagnostic and therapeutic interventions in the critically ill. In a prospective study reliability and costs of two POC lactate testing devices were compared to the central laboratory lactate monitoring method. Methods: From arterial whole blood and capillary blood samples of 40 intensive care unit (ICU) patients lactate concentrations were measured using either a battery-powered handheld lactate analyser (Accusport(R)) or a bench-top blood gas analyser (Chiron 865 series) and compared with lactate measured by the hospital's central laboratory ('reference' method). Measurements were carried out on the day of inclusion in the study ('baseline'), 8 h later, and in the morning of the 1st, 2nd, and 3rd days thereafter. Costs for blood lactate measurements were analysed for each method. Results: A total of 197 lactate measurements were done with each system. Lactate measured from arterial blood using the Accusport(R) and the central laboratory showed excellent agreement (bias: -0.15 mmol/l; relative error: -2.74%). Lactate measured by the blood gas analyser had also excellent agreement with the reference method (bias: 0.09 mmol/l; relative error: 2.24%) and the hand-held device (bias: -0.24 mmol/l; relative error: -5.06%). Time from blood sampling to availability of data was significantly longer for the central laboratory (85+/-35 min [range: 45-168 min]) than for both POC systems (range: 1-10 [range: 45-168 min]) than for both POC systems (range: 1-10 min). Total cost for measuring blood lactate was lowest using the Accusport(R) device. Conclusion: The trend towards miniaturizing laboratory monitoring devices will continue, resulting in greater flexibility of management of the critically ill. Blood lactate can rapidly, easily, accurately, and economically be measured at the bedside with the hand-held monitor apparatus Accusport(R) and the bench-top blood gas analyser.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 26 条
[1]   LACTATE CLEARANCE AND SURVIVAL FOLLOWING INJURY [J].
ABRAMSON, D ;
SCALEA, TM ;
HITCHCOCK, R ;
TROOSKIN, SZ ;
HENRY, SM ;
GREENSPAN, J .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (04) :584-589
[2]   BLOOD LACTATE LEVELS ARE SUPERIOR TO OXYGEN-DERIVED VARIABLES IN PREDICTING OUTCOME IN HUMAN SEPTIC SHOCK [J].
BAKKER, J ;
COFFERNILS, M ;
LEON, M ;
GRIS, P ;
VINCENT, JL .
CHEST, 1991, 99 (04) :956-962
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   EXCESS LACTATE - INDEX OF REVERSIBILITY OF SHOCK IN HUMAN PATIENTS [J].
BRODER, G ;
WEIL, MH .
SCIENCE, 1964, 143 (361) :1457-&
[5]   Evidence for early supply independent mitochondrial dysfunction in patients developing multiple organ failure after trauma [J].
Cairns, CB ;
Moore, FA ;
Haenel, JB ;
Gallea, BL ;
Ortner, JP ;
Rose, SJ ;
Moore, EE .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (03) :532-536
[6]  
CASTRO JH, 1995, AM J CLIN PATHOL S1, V104, pS95
[7]  
DECRESCE RP, 1995, ARCH PATHOL LAB MED, V119, P898
[8]  
DESPOTIS GJ, 1994, J THORAC CARDIOV SUR, V107, P271
[9]  
JACOBS E, 1995, AM J CLIN PATHOL, V104, pS33
[10]  
KEFFER JH, 1995, AM J CLIN PATHOL, V104, pS107