Diffuse optical tomography with a priori anatomical information

被引:130
作者
Guven, M [1 ]
Yazici, B
Intes, X
Chance, B
机构
[1] Rensselaer Polytech Inst, Elect Comp & Syst Engn Dept, Troy, NY 12181 USA
[2] Univ Penn, Dept Biophys & Biochem, Philadelphia, PA 19104 USA
关键词
D O I
10.1088/0031-9155/50/12/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diffuse optical tomography (DOT) poses a typical ill-posed inverse problem with a limited number of measurements and inherently low spatial resolution. In this paper, we propose a hierarchical Bayesian approach to improve spatial resolution and quantitative accuracy by using a priori information provided by a secondary high resolution anatomical imaging modality, such as magnetic resonance (MR) or x-ray. In such a dual imaging approach, while the correlation between optical and anatomical images may be high, it is not perfect. For example, a tumour may be present in the optical image, but may not be discernable in the anatomical image. The proposed hierarchical Bayesian approach allows incorporation of partial a priori knowledge about the noise and unknown optical image models, thereby capturing the function-anatomy correlation effectively. We present a computationally efficient iterative algorithm to simultaneously estimate the optical image and the unknown a priori model parameters. Extensive numerical simulations demonstrate that the proposed method avoids undesirable bias towards anatomical prior information and leads to significantly improved spatial resolution and quantitative accuracy.
引用
收藏
页码:2837 / 2858
页数:22
相关论文
共 68 条
[1]   PHOTON-MEASUREMENT DENSITY-FUNCTIONS .1. ANALYTICAL FORMS [J].
ARRIDGE, SR .
APPLIED OPTICS, 1995, 34 (31) :7395-7409
[2]   Optical imaging in medicine .2. Modelling and reconstruction [J].
Arridge, SR ;
Hebden, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (05) :841-853
[3]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[4]  
ARRIDGE SR, 1993, MED OPTICAL TOMOGRAP, V11, P53
[5]   MRI-guided optical tomography: Prospects and computation for a new imaging method [J].
Barbour, RL ;
Graber, HL ;
Chang, JW ;
Barbour, SLS ;
Koo, PC ;
Aronson, R .
IEEE COMPUTATIONAL SCIENCE & ENGINEERING, 1995, 2 (04) :63-77
[6]  
Berry D., 1988, STAT DECISION THEORY
[7]   Imaging the body with diffuse optical tomography [J].
Boas, DA ;
Brooks, DH ;
Miller, EL ;
DiMarzio, CA ;
Kilmer, M ;
Gaudette, RJ ;
Zhang, Q .
IEEE SIGNAL PROCESSING MAGAZINE, 2001, 18 (06) :57-75
[8]   Near-infrared (NIR) tomography breast image reconstruction with a priori structural information from MRI:: Algorithm development for reconstructing heterogeneities [J].
Brooksby, BA ;
Dehghani, H ;
Pogue, BW ;
Paulsen, KD .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2003, 9 (02) :199-209
[9]   Sources of absorption and scattering contrast for near-infrared optical mammography [J].
Cerussi, AE ;
Berger, AJ ;
Bevilacqua, F ;
Shah, N ;
Jakubowski, D ;
Butler, J ;
Holcombe, RF ;
Tromberg, BJ .
ACADEMIC RADIOLOGY, 2001, 8 (03) :211-218
[10]   Imaging of fluorescence in highly scattering media [J].
Chang, JH ;
Graber, HL ;
Barbour, RL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (09) :810-822