Usefulness of intravascular ultrasound in preventing stenting of hazy areas adjacent to coronary stents and its support of support spot-stenting

被引:13
作者
Grewal, J [1 ]
Ganz, P [1 ]
Selwyn, A [1 ]
Kinlay, S [1 ]
机构
[1] Brigham & Womens Hosp, Div Cardiovasc Med, Cardiac Catheterizat Lab, Boston, MA 02115 USA
关键词
D O I
10.1016/S0002-9149(01)01513-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The uncertain significance of hazy areas at the margins of coronary stents may lead to further, at times unnecessary, stenting. However, the risk of restenosis increases substantially when additional stents are deployed. We used intravascular ultrasound (IVUS) to identify the causes of hazy segments adjacent to stents. We identified 13 cases with hazy regions adjacent to coronary stents and 20 controls without hazy regions matched by age, gender, and vessel stented. Hazy regions were defined from the angiogram as reduced contrast density without a clearly defined intimal tear, dissection, thrombus, or stenosis (> 50%). IVUS images were obtained from the reference, stent, and hazy and control regions adjacent to the stent. Computerized planimetery was used to measure the vessel, lumen, and plaque cross-sectional areas (CSAs), the maximum are of calcium, and the eccentricity ratio (minimum:maximum lumen diameter). There were no significant differences between hazy and control segments in the vessel, lumen, and plaque CSAs. All lumen CSAs were >4.0 mm(2). Compared with control regions, the hazy regions had calcified plaque more often (69% vs 25%; odds ratio [OR] 6.75, 95% confidence intervals [CI] 1.82 to 25.0]) and more frequent intimal tears (23% vs 0%, OR 6.67, 95% CI 1.98 to 35.0). Haziness was particularly associated with calcified plaque and eccentric lumen (p = 0.037). Thus, haziness at the margins of coronary stents is often caused by calcified plaque, IVUS can differentiate calcified plaques from intimal tears and thereby obviate unnecessary stenting. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:1246 / 1249
页数:4
相关论文
共 22 条
[1]   Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions [J].
Abizaid, AS ;
Mintz, GS ;
Mehran, R ;
Abizaid, A ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Wu, HS ;
Pappas, C ;
Kent, KM ;
Leon, MB .
CIRCULATION, 1999, 100 (03) :256-261
[2]   CORONARY ANGIOGRAPHIC MORPHOLOGY IN MYOCARDIAL-INFARCTION - A LINK BETWEEN THE PATHOGENESIS OF UNSTABLE ANGINA AND MYOCARDIAL-INFARCTION [J].
AMBROSE, JA ;
WINTERS, SL ;
ARORA, RR ;
HAFT, JI ;
GOLDSTEIN, J ;
RENTROP, KP ;
GORLIN, R ;
FUSTER, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (06) :1233-1238
[3]  
COWLEY MJ, 1984, AM J CARDIOL, V53, P12
[4]   RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE [J].
ELLIS, SG ;
SAVAGE, M ;
FISCHMAN, D ;
BAIM, DS ;
LEON, M ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
TEIRSTEIN, PS ;
WALKER, C ;
BAILEY, S ;
BUCHBINDER, M ;
TOPOL, EJ ;
SCHATZ, RA .
CIRCULATION, 1992, 86 (06) :1836-1844
[5]   CONTRIBUTION OF LOCALIZED CALCIUM DEPOSITS TO DISSECTION AFTER ANGIOPLASTY - AN OBSERVATIONAL STUDY USING INTRAVASCULAR ULTRASOUND [J].
FITZGERALD, PJ ;
PORTS, TA ;
YOCK, PG .
CIRCULATION, 1992, 86 (01) :64-70
[6]   SUBACUTE THROMBOTIC COMPLICATIONS AFTER INTRACORONARY IMPLANTATION OF PALMAZ-SCHATZ STENTS [J].
HAUDE, M ;
ERBEL, R ;
ISSA, H ;
STRAUB, U ;
RUPPRECHT, HJ ;
TREESE, N ;
MEYER, J .
AMERICAN HEART JOURNAL, 1993, 126 (01) :15-22
[7]   MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING [J].
HONYE, J ;
MAHON, DJ ;
JAIN, A ;
WHITE, CJ ;
RAMEE, SR ;
WALLIS, JB ;
ALZARKA, A ;
TOBIS, JM .
CIRCULATION, 1992, 85 (03) :1012-1025
[8]   Stented segment length as an independent predictor of restenosis [J].
Kobayashi, Y ;
De Gregorio, J ;
Kobayashi, N ;
Akiyama, T ;
Reimers, B ;
Finci, L ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (03) :651-659
[9]   Comparison of immediate and follow-up results of the short and long NIR stent with the Palmaz-Schatz stent [J].
Kobayashi, Y ;
De Gregorio, J ;
Kobayashi, N ;
Reimers, B ;
Albiero, R ;
Vaghetti, M ;
Finci, L ;
Di Mario, C ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (05) :499-504
[10]   STRATIFICATION OF THE RISK OF THROMBOSIS AFTER INTRACORONARY STENTING FOR THREATENED OR ACUTE CLOSURE COMPLICATING CORONARY BALLOON ANGIOPLASTY - A COOK REGISTRY STUDY [J].
LIU, MW ;
VOORHEES, WD ;
AGRAWAL, S ;
DEAN, LS ;
ROUBIN, GS .
AMERICAN HEART JOURNAL, 1995, 130 (01) :8-13