Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode

被引:115
作者
Dai, Z
Chen, J
Yan, F
Ju, HX [1 ]
机构
[1] Nanjing Univ, Dept Chem, Inst Biol Chem, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Canc Hosp & Inst Jiangsu Prov, Dept Med Examinat, Nanjing 210009, Peoples R China
来源
CANCER DETECTION AND PREVENTION | 2005年 / 29卷 / 03期
基金
中国国家自然科学基金;
关键词
sensors; CEA; thionine; gold electrode; self-assembled monolayer; HRP; ELISA; immunoassay;
D O I
10.1016/j.cdp.2004.12.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
A sensor based on thionine monolayer modified gold electrode for determination of carcinoembryonic antigen (CEA) in human serum is proposed. The sensor is prepared by covalently binding thionine to a cysteamine self-assembled monolayer with p-phthaloyl chloride as a linkage, which gives a surface coverage of 8.97 +/- 3.28 x 10(-12) mol/cm(2) for thionine. The electrochemistry of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 1.47 +/- 0.84 s(-1). Based on an electrochemical enzyme-linked immunoassay by using the immobilized thionine as an electron transfer mediator between the electrode and the horseradish peroxidase (HR-P) labeled anti-CEA antibody, a calibration curve with two linear ranges from 0.6 to 17 and 17 to 200 ng/mL and a detection limit of 0.2 ng/mL for CEA determination is obtained in pH 4.2 PBS containing 2.0 mmol/L H2O2 and 0.5 mol/L NaCl. The sensor shows a good accuracy. The precision and reproducibility are acceptable with the intra-assay CV of 4.9% and 5.9% at 10 and 100 ng/mL CEA concentrations, respectively, and the inter-assays CV of 7.8% at 100 ng/mL CEA. The response of thionine modified electrode shows only 1.6% decrease after 100 replicate measurements and the storage stability is acceptable in a pH 7.0 PBS at 4 degrees C for 1 week. The method avoids the addition of electron transfer mediator to the solution, thus is much simpler. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis. (c) 2005 International Society for Preventive Oncology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 41 条
[1]
[Anonymous], LUNG CANC
[2]
Bremer K., 1995, EUR J CANCER, V31, pS262
[3]
Cameiro C., 1998, EUR J CANCER, V34, pS43
[4]
Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[5]
Chiem NH, 1998, CLIN CHEM, V44, P591
[6]
Monoclonal antibody binding affinity determined by microchip-based capillary electrophoresis [J].
Chiem, NH ;
Harrison, DJ .
ELECTROPHORESIS, 1998, 19 (16-17) :3040-3044
[7]
Serum anti-p53 antibodies in lung cancer: comparison with established tumor markers [J].
Cioffi, M ;
Vietri, MT ;
Gazzerro, P ;
Magnetta, R ;
D'Auria, A ;
Durante, A ;
Nola, E ;
Puca, GA ;
Molinari, AM .
LUNG CANCER, 2001, 33 (2-3) :163-169
[8]
A reusable amperometric biosensor based on a novel silver-epoxy electrode for immunoglobulin detection [J].
Dutra, RF ;
Coelho, GD ;
Silva, VL ;
Ledingham, WM ;
Lima, JL .
BIOTECHNOLOGY LETTERS, 2000, 22 (07) :579-583
[9]
Carcinoembryonic antigen (CEA) presentation and specific T cell-priming by human dendritic cells transfected with CEA-mRNA [J].
Eppler, E ;
Hörig, H ;
Kaufman, HL ;
Groscurth, P ;
Filgueira, L .
EUROPEAN JOURNAL OF CANCER, 2002, 38 (01) :184-193
[10]
Competitive enzyme immunosensor developed on a renewable carbon paste electrode support [J].
Fernández-Sánchez, C ;
Costa-García, A .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :119-127