Fourier transform Raman spectroscopy of polyacrylamide gels (PAGs) for radiation dosimetry

被引:104
作者
Baldock, C
Rintoul, L
Keevil, SF
Pope, JM
George, GA
机构
[1] Queensland Univ Technol, Sch Phys Sci, Ctr Med & Hlth Phys, Brisbane, Qld 4001, Australia
[2] Queensland Univ Technol, Ctr Instrumental & Dev Chem, Brisbane, Qld 4001, Australia
[3] Univ London, United Med & Dent Sch, Guys Hosp, Div Radiol Sci, London, England
关键词
D O I
10.1088/0031-9155/43/12/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyacrylamide gels (PAGs) are used for magnetic resonance imaging radiation dosimetry. Fourier transform (FT) Raman spectroscopy studies were undertaken to investigate cross-linking changes during the copolymerization of polyacrylamide gels in the spectral range of 200-3500 cm(-1). Vibrational bands of 1285 cm(-1) and 1256 cm(-1) were assigned to acrylamide and bis-acrylamide single CH2 delta(CH2) binding modes. Bands were found to decrease in amplitude with increasing absorbed radiation dose as a result of copolymerization. Principal component regression was performed on FT-Raman spectra of FAG samples irradiated to 50 Gy. Two components were found to be sufficient to account for 98.7% of the variance in the data. Cross validation was used to establish the absorbed radiation dose of an unknown FAG sample from the FT-Raman spectra. The calculated correlation coefficient between measured and predictive samples was 0.997 with a standard error of estimate of 0.976 and a standard error of prediction of 1.140. Results demonstrate the potential of FT-Raman spectroscopy for ionizing radiation dosimetry using polyacrylamide gels.
引用
收藏
页码:3617 / 3627
页数:11
相关论文
共 46 条
[1]   CHARACTERIZATION OF POLYACRYLAMIDE-GEL FORMATION AND STRUCTURE BY SURFACE-ENHANCED RAMAN-SPECTROSCOPY [J].
AHERN, AM ;
GARRELL, RL .
LANGMUIR, 1988, 4 (05) :1162-1168
[2]   THE DEGRADATION OF SOLID POLYMETHYLMETHACRYLATE BY IONIZING RADIATION [J].
ALEXANDER, P ;
CHARLESBY, A ;
ROSS, M .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1954, 223 (1154) :392-404
[3]  
Allen G, 1989, COMPREHENSIVE POLYM
[4]   GEL DOSIMETER FOR DEPTH-DOSE MEASUREMENTS [J].
ANDREWS, HL ;
MURPHY, RE ;
LEBRUN, EJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1957, 28 (05) :329-332
[5]  
[Anonymous], MED PHYS
[6]  
[Anonymous], MED PHYS
[7]   Multiple-site fast exchange model for spin-lattice relaxation in the Fricke-gelatin dosimeter [J].
Audet, C ;
Schreiner, LJ .
MEDICAL PHYSICS, 1997, 24 (02) :201-209
[8]  
AUDET C, 1993, P INT SOC MAGN RES M, P705
[9]  
Audet C., 1995, THESIS MCGILL U MONT
[10]   DIFFUSION IN FE(II/III) RADIATION-DOSIMETRY GELS MEASURED BY MAGNETIC-RESONANCE-IMAGING [J].
BALCOM, BJ ;
LEES, TJ ;
SHARP, AR ;
KULKARNI, NS ;
WAGNER, GS .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (10) :1665-1676