Optimization and clinical use of multisegment intensity-modulated radiation therapy for high-dose conformal therapy

被引:75
作者
Fraass, BA
Kessler, ML
McShan, DL
Marsh, LH
Watson, BA
Dusseau, WJ
Eisbruch, A
Sandler, HM
Lichter, AS
机构
[1] UM, Jackson, MI USA
[2] WA Foote Hosp, Paul Tejada Ctr Radiat Oncol, Jackson, MI USA
[3] UM, Lansing, MI USA
[4] Ingham Reg Med Ctr, Dept Radiat Oncol, Lansing, MI USA
关键词
D O I
10.1016/S1053-4296(99)80055-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) may be performed with many different treatment delivery techniques. This article summarizes the clinical use and optimization of multisegment IMRT plans that have been used to treat more than 350 patients with IMRT over the last 4.5 years. More than 475 separate clinical IMRT plans are reviewed, including treatments of brain, head and neck, thorax, breast and chest wall, abdomen, pelvis, prostate, and other sites. Clinical planning, plan optimization, and treatment delivery are summarized, including efforts to minimize the number of additional intensity- modulated segments needed for particular planning protocols. Interactive and automated optimization of segmental and full IMRT approaches are illustrated, and automation of the segmental IMRT planning process is discussed.
引用
收藏
页码:60 / +
页数:22
相关论文
共 107 条
  • [1] Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer
    Armstrong, J
    Raben, A
    Zelefsky, M
    Burt, M
    Leibel, S
    Burman, C
    Kutcher, G
    Harrison, L
    Hahn, C
    Ginsberg, R
    Rusch, V
    Kris, M
    Fuks, Z
    [J]. RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) : 17 - 22
  • [2] 3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER
    ARMSTRONG, JG
    BURMAN, C
    LEIBEL, S
    FONTENLA, D
    KUTCHER, G
    ZELEFSKY, M
    FUKS, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04): : 685 - 689
  • [3] Balter JM, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P182
  • [4] BALTER JM, 1997, MED PHYS, V24, P1002
  • [5] Scanned intensity modulations for 50 MV photons
    Blomquist, M
    Satherberg, A
    Karlsson, M
    Zackrisson, B
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) : 1185 - 1197
  • [6] REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS
    BORTFELD, T
    BOYER, AL
    SCHLEGEL, W
    KAHLER, DL
    WALDRON, TJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04): : 899 - 908
  • [7] Modulated beam conformal therapy for head and neck tumors
    Boyer, AL
    Geis, P
    Grant, W
    Carol, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01): : 227 - 236
  • [8] OPTIMAL DOSE DISTRIBUTION FOR ERADICATION OF HETEROGENEOUS TUMORS
    BRAHME, A
    AGREN, AK
    [J]. ACTA ONCOLOGICA, 1987, 26 (05) : 377 - 385
  • [9] DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW
    BRAHME, A
    [J]. ACTA ONCOLOGICA, 1987, 26 (06) : 403 - 412
  • [10] OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES
    BRAHME, A