Osseointegration of a hydroxyapatite-coated multilayered mesh stem

被引:39
作者
Kusakabe, H
Sakamaki, T
Nihei, K
Oyama, Y
Yanagimoto, S
Ichimiya, M
Kimura, J
Toyama, Y
机构
[1] Natl Ctr Child Hlth & Dev, Dept Orthoped Surg, Setagaya Ku, Tokyo 1578535, Japan
[2] Keio Univ, Sch Med, Dept Orthoped Surg, Tokyo, Japan
[3] Kyocera Corp, Bioceram Med Proc Res Sect, Shiga, Japan
[4] Keio Univ, Sch Med, Lab Anim Ctr, Tokyo, Japan
基金
日本学术振兴会;
关键词
multilayered mesh; hydroxyapatite coating; cementless hip prosthesis; weight-bearing model; osseointegration;
D O I
10.1016/j.biomaterials.2003.09.090
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new type of porous coating for hip prostheses called "multilayered mesh" was tested under weight-bearing conditions. The surface of the stem is constructed of titanium mesh produced by etching. The hip stems of hydroxyapatite (HA)-coated multilayered mesh and conventional beads were implanted into canine right hips, and animals were killed 3. 6 and 10 weeks and 6 and 12 months after implantation. Shear strength between the implant and the bone was evaluated by the push-out test. Bone ingrowth was calculated from backscattered electron imaging-scanning electron microscopy (BEI-SEM) images of transverse sections. Toluidine blue stained sections and the BEI-SEM images were evaluated histologically. The break sites of the specimens after the push-out test were evaluated on BEI-SEM images of longitudinal sections. The mean push-out strength of the HA-coated multilayered mesh samples was greater than that of the beads-coated samples every time tested, and the HA-coated multilayered mesh implants had significantly stronger push-out strength at 3 and 6 weeks (P < 0.05). The strenght of the HA-coated multilayered mesh implants was even greater at 6 and 12 months, whereas the strength of the beads-coated samples decreased. The HA-coated multilayered mesh implants showed significantly higher percentages of bone ingrowth than the beads-coated implants every time tested, except at 6 months (p < 0.05). At 6 and 12 months, the bone ingrowth data for the HA-coated multilayered mesh implants increased, whereas it decreased for the beads-coated implants. The new bone formation had reached the bottom of the porous area of the HA-coated multilayered mesh surface by 3 weeks, but not had reached the bottom of the conventional beads surface. At 6 and 12 months, the smaller pores of the bead surface stopped the thickening of trabecular bone, and at 12 months, the break sites were at the bone-implant interface of the bead Surface, whereas they were on the bone side of the HA-coated multilayered mesh surface. The difference between the break sites was significant at 12 months (p < 0.05). The HA-coated multilayered mesh stem provided faster, stronger, and more durable osseointegration than the conventional bead stem. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2957 / 2969
页数:13
相关论文
共 102 条
[1]   Osteoinduction, osteoconduction and osseointegration [J].
Albrektsson, T ;
Johansson, C .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S96-S101
[2]   IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[3]  
Bellemans J, 1999, ACTA ORTHOP SCAND, V70, P1
[4]  
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P263
[5]  
CAMERON HU, 1994, BONE IMPLANT INTERFA, P145
[6]   Hydroxyapatite-coated total hip femoral components in patients less than fifty years old - Clinical and radiographic results after five to eight years of follow-up [J].
Capello, WN ;
DAntonio, JA ;
Feinberg, JR ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1023-1029
[7]   Hydroxyapatite in total hip arthroplasty -: Clinical results and critical issues [J].
Capello, WN ;
D 'Antonio, JA ;
Manley, MT ;
Feinberg, JR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) :200-211
[8]   Osteoconduction at porous hydroxyapatite with various pore configurations [J].
Chang, BS ;
Lee, CK ;
Hong, KS ;
Youn, HJ ;
Ryu, HS ;
Chung, SS ;
Park, KW .
BIOMATERIALS, 2000, 21 (12) :1291-1298
[9]  
Chang YL, 1999, J ORAL MAXIL SURG, V57, P1096
[10]  
Cook S D, 1987, Int J Oral Maxillofac Implants, V2, P15