Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model

被引:89
作者
Manke, D [1 ]
Nehrke, K [1 ]
Börnert, P [1 ]
机构
[1] Sector Tech Syst, Philips Res Labs, D-22335 Hamburg, Germany
关键词
coronary MR angiography; respiratory motion; prospective motion correction; motion model; model calibration;
D O I
10.1002/mrm.10483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel technique is presented which enables the calibration of a 3D affine respiratory motion model to the individual motion pattern of the patient. The concept of multiple navigators and precursory navigators is introduced to address nonlinear properties and hysteresis effects of the model parameters with respect to the conventional diaphragmatic navigator. The optimal combination and weighting of the navigators is determined on the basis of a principal component analysis (PCA). Thus, based on a given navigator measurement the current motion state of the object can be predicted by means of the calibrated motion model. The 3D motion model is applied in high-resolution coronary MR angiography examinations (CMRA) to prospectively correct for respiration-induced motion. The basic feasibility of the proposed calibration procedure was shown in 16 volunteers. Furthermore, the application of the calibrated motion model for CMRA examinations of the right coronary artery (RCA) was tested in 10 volunteers. The superiority of a calibrated 313 translation model over the conventional 1 D translation model with a fixed correction factor and the potential of affine prospective motion correction for CMRA are demonstrated. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:122 / 131
页数:10
相关论文
共 32 条
  • [1] Prospective navigator correction of image position for coronary MR angiography
    Danias, PG
    McConnell, MV
    Khasgiwala, VC
    Chuang, ML
    Edelman, RR
    Manning, WJ
    [J]. RADIOLOGY, 1997, 203 (03) : 733 - 736
  • [2] Dynamic scan-plane tracking using MR position monitoring
    Derbyshire, JA
    Wright, GA
    Henkelman, RM
    Hinks, RS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 924 - 932
  • [3] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [4] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [5] Amplitude demodulation of the electrocardiogram signal (ECG) for respiration monitoring and compensation during MR examinations
    Felblinger, J
    Boesch, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) : 129 - 136
  • [6] Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
  • [7] 2-9
  • [8] Vessel tracking: Prospective adjustment of section-selective MR angiographic locations for improved coronary artery visualization over the cardiac cycle
    Foo, TKF
    Ho, VB
    Hood, MN
    [J]. RADIOLOGY, 2000, 214 (01) : 283 - 289
  • [9] HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
  • [10] Jolliffe I., 2002, PRINCIPAL COMPONENT, DOI [DOI 10.1016/0169-7439(87)80084-9, 10.1007/0-387-22440-8_13, DOI 10.1007/0-387-22440-8_13]