Comparison of two different methods using overlapping synthetic peptides for localizing linear B cell epitopes in the U1 snRNP-C autoantigen

被引:18
作者
Halimi, H [1 ]
Dumortier, H [1 ]
Briand, JP [1 ]
Muller, S [1 ]
机构
[1] CNRS,UPR 9021,INST BIOL MOL & CELLULAIRE,F-67000 STRASBOURG,FRANCE
关键词
B epitope; synthetic peptide; SPOTscan; U1 small nuclear ribonucleoprotein complex; autoantibody; systemic lupus erythematosus;
D O I
10.1016/S0022-1759(96)00171-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have compared the performances of two different approaches using overlapping synthetic peptides to identify the location of linear epitopes of the U1 snRNP-C autoantigen, The first method was based on the use of 15 overlapping peptides (16-30 residue-long) synthesized using conventional Fmoc chemistry, removed from the resin by a standard cleavage procedure, and tested by ELISA after direct coating to polyvinyl microtiter plates. The second approach used a commercial kit (SPOT) to synthesize 75 overlapping decapeptides on cellulose membrane which were assayed by a direct immunoenzymatic test. Both standard and SPOTscan methods were evaluated with antibodies raised in rabbits against synthetic peptides of U1C and sera from patients with autoimmune diseases. In addition to inherent problems linked to the SPOT synthesis (in particular the impossibility of checking the quality of peptides), a number of limitations in the SPOTscan method were identified (e.g. a certain lack of sensitivity and, in one case, the complete lack of peptide reactivity due to the removal of charged end groups at both extremities). However, we found no background with sera from autoimmune patients in the SPOTscan and the antigenic maps obtained using the two approaches generally agreed. This study shows that the SPOTscan approach represents a simple, relatively non expensive and rapid method for initial screening to identify candidate sequences that may be dominant linear epitopes in a protein. Subsequent analysis and controls should include the preparation of conventionally synthesized peptides for formal immunochemical investigations.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 30 条
[1]  
BARAKAT S, 1992, CLIN EXP IMMUNOL, V89, P38
[2]  
BARAKAT S, 1991, CLIN EXP IMMUNOL, V86, P71
[3]  
BARAKAT S, 1990, CLIN EXP IMMUNOL, V81, P256
[4]   RETRO-INVERSO PEPTIDOMIMETICS AS NEW IMMUNOLOGICAL PROBES - VALIDATION AND APPLICATION TO THE DETECTION OF ANTIBODIES IN RHEUMATIC DISEASES [J].
BRIAND, JP ;
GUICHARD, G ;
DUMORTIER, H ;
MULLER, S .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1995, 270 (35) :20686-20691
[5]   USE OF SYNTHETIC PEPTIDES FOR THE DETECTION AND QUANTIFICATION OF AUTOANTIBODIES [J].
ELKON, KB .
MOLECULAR BIOLOGY REPORTS, 1992, 16 (03) :207-212
[6]   SPOT-SYNTHESIS - AN EASY TECHNIQUE FOR THE POSITIONALLY ADDRESSABLE, PARALLEL CHEMICAL SYNTHESIS ON A MEMBRANE SUPPORT [J].
FRANK, R .
TETRAHEDRON, 1992, 48 (42) :9217-9232
[7]   SIMULTANEOUS MULTIPLE PEPTIDE-SYNTHESIS UNDER CONTINUOUS-FLOW CONDITIONS ON CELLULOSE PAPER DISKS AS SEGMENTAL SOLID SUPPORTS [J].
FRANK, R ;
DORING, R .
TETRAHEDRON, 1988, 44 (19) :6031-6040
[8]   STRATEGIES FOR EPITOPE ANALYSIS USING PEPTIDE-SYNTHESIS [J].
GEYSEN, HM ;
RODDA, SJ ;
MASON, TJ ;
TRIBBICK, G ;
SCHOOFS, PG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 102 (02) :259-274
[9]   USE OF PEPTIDE-SYNTHESIS TO PROBE VIRAL-ANTIGENS FOR EPITOPES TO A RESOLUTION OF A SINGLE AMINO-ACID [J].
GEYSEN, HM ;
MELOEN, RH ;
BARTELING, SJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1984, 81 (13) :3998-4002
[10]   Serum antibodies from patients with primary Sjogren's syndrome and systemic lupus erythematosus recognize multiple epitopes on the La(SS-B) autoantigen resembling viral protein sequences [J].
Haaheim, LR ;
Halse, AK ;
Kvakestad, R ;
Stern, B ;
Normann, O ;
Jonsson, R .
SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1996, 43 (01) :115-121