Techno-economic evaluation of various hybrid power systems for rural telecom

被引:78
作者
Amutha, W. Margaret [1 ]
Rajini, V. [1 ]
机构
[1] SSN Coll Engn, Madras, Tamil Nadu, India
关键词
Hybrid power system; Optimisation; Hybrid Optimisation Model for Electric Renewable (HOMER); Modelling;
D O I
10.1016/j.rser.2014.10.103
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nowadays, utility has started to consider the green power technology for having a healthier environment. The green power technologies reduce combustion of fossil fuels and the consequent CO2 emission which is the principle cause of global warming. By maximising the use of the renewable energy, the usage of diesel generator for powering the base transceiver stations could be reduced or removed. This paper aims to investigate the economic, technical and environmental performance of various hybrid power systems for powering remote telecom. Simulations using Hybrid Optimisation Model for Electric Renewable (HOMER) software are performed to determine the Initial Capital, the Total Net Present Cost (TNPC), the Cost of Energy (COE) as well as the system Capacity Shortage of the different supply options. The simulation results suggest a suitable hybrid system which would be the feasible solution for generation of electric power for remote telecom. A detailed analysis, description and modelling of the system are also presented in this paper. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:553 / 561
页数:9
相关论文
共 22 条
[1]  
Aghaei J, 2013, IEEE SYST J, V9, P1
[2]  
Ahmadi A, 2011, 19 IR C EL ENG ICEE, P1097
[3]   Development and Power Performance Test of a Small Three-Blade Horizontal-Axis Wind Turbine [J].
Ajao, K. R. ;
Adegun, I. K. .
HEAT TRANSFER RESEARCH, 2009, 40 (08) :777-792
[4]  
[Anonymous], 2014, INT J EMERG TECHNOL
[5]   Simulation and optimization of stand-alone hybrid renewable energy systems [J].
Bernal-Agustin, Jose L. ;
Dufo-Lopez, Rodolfo .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08) :2111-2118
[6]   OPTIMUM PHOTOVOLTAIC ARRAY SIZE FOR A HYBRID WIND PV SYSTEM [J].
BOROWY, BS ;
SALAMEH, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (03) :482-488
[7]   Characterisation of a 3 kW PEFC power system coupled with a metal hydride H2 storage [J].
Bossi, C. ;
Del Corno, A. ;
Scagliotti, M. ;
Valli, C. .
JOURNAL OF POWER SOURCES, 2007, 171 (01) :122-129
[8]  
Carsten Hansen Jens, 2007, 4 RIS NAT LAB, P21
[9]  
Enache SD, 2014, P INT C OPT EL EL EQ, P174
[10]   Risk constrained self-scheduling of hydro/wind units for short term electricity markets considering intermittency and uncertainty [J].
Ghadikolaei, Hadi Moghimi ;
Ahmadi, Abdollah ;
Aghaei, Jamshid ;
Najafi, Meysam .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (07) :4734-4743