On the development of a biomechatronic system to record tendon sliding movements

被引:9
作者
Cavallaro, E
Cappiello, G
Micera, S [1 ]
Carrozza, MC
Rantanen, P
Dario, P
机构
[1] Scuola Super Sant Anna, ARTS Lab, I-56127 Pisa, Italy
[2] ORTON Invalid Fdn, Helsinki 00280, Finland
关键词
biomechatronics; FNS; fuzzy inference systems; neuroprostheses; tendon biomechanics;
D O I
10.1109/TBME.2005.846711
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main goal of this paper is to study the feasibility of a novel implantable micro-system able to record information about tendon sliding movements by using contactless measurement devices (magnetic sources and sensors). The system, named "Biomechatronic Position Transducer" (BPT), can be used for the implementation of advanced control strategies in neuroprostheses. After a preliminary analysis based on finite element model simulations, an experimental setup was developed in order to simulate the recording conditions (the sensors fixed to the bones and the magnetic sources placed on the tendons). In order to limit the number of implanted components of the system, a fuzzy Mamdani-like architecture was developed to extract the information from the raw data. The results confirm the possibility of using the presented approach for developing an implantable micro-sensor able to extract kinematic information useful for the control of neuroprostheses. Future works will go in the direction of integrating and testing the sensors and the electronic circuitry (to provide power supply and to record the data) during in vitro and in situ experiments.
引用
收藏
页码:1110 / 1119
页数:10
相关论文
共 13 条
[1]   A. sensorized thumb for force closed-loop control of hand neuroprostheses [J].
Carpaneto, J ;
Micera, S ;
Zaccone, F ;
Vecchi, F ;
Dario, P .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (04) :346-353
[2]   FEEDBACK-REGULATION OF HAND GRASP OPENING AND CONTACT FORCE DURING STIMULATION OF PARALYZED MUSCLE [J].
CRAGO, PE ;
NAKAI, RJ ;
CHIZECK, HJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (01) :17-28
[3]  
Haugland M, 1999, IEEE Trans Rehabil Eng, V7, P215, DOI 10.1109/86.769412
[4]   MAGNETIC-FIELD EFFECTS ON BIOMOLECULES, CELLS, AND LIVING ORGANISMS [J].
HONG, FT .
BIOSYSTEMS, 1995, 36 (03) :187-229
[5]  
Johnson M W, 1999, IEEE Trans Rehabil Eng, V7, P349, DOI 10.1109/86.788471
[6]  
Memberg WD, 1997, J REHABIL RES DEV, V34, P82
[7]   Neuro-fuzzy extraction of angular information from muscle afferents for ankle control during standing in paraplegic subjects:: An animal model [J].
Micera, S ;
Jensen, W ;
Sepulveda, F ;
Riso, RR ;
Sinkjær, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (07) :787-794
[8]   The shape of fuzzy sets in adaptive function approximation [J].
Mitaim, S ;
Kosko, B .
IEEE TRANSACTIONS ON FUZZY SYSTEMS, 2001, 9 (04) :637-656
[9]   Selection of appropriate defuzzification methods using application specific properties [J].
Runkler, TA .
IEEE TRANSACTIONS ON FUZZY SYSTEMS, 1997, 5 (01) :72-79
[10]   HUMAN EXPOSURE TO STATIC AND TIME-VARYING MAGNETIC-FIELDS [J].
STUCHLY, MA .
HEALTH PHYSICS, 1986, 51 (02) :215-225