Coupling of a supercritical fluid chromatography system to a hybrid (Q-TOF 2) mass spectrometer: on-line accurate mass measurements

被引:12
作者
Garzotti, M [1 ]
Rovatti, L [1 ]
Hamdan, M [1 ]
机构
[1] Glaxo Wellcome SpA, GlaxoSmithKline Grp, Med Res Ctr, I-37135 Verona, Italy
关键词
D O I
10.1002/rcm.364
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This note describes a simple and economical method to couple a supercritical fluid chromatography (SFC) system (Berger Instruments, US) with a high-resolution hybrid mass spectrometer (Q-TOF 2; Micromass, UK). This experimental arrangement has three distinct advantages: (1) coupling between the two systems can be effected without the need for an interface or hardware modifications of either system, (ii) this experimental arrangement provides on-line accurate mass SFC/MS measurements which are indispensable for the characterisation of new chemical entities and unknown metabolites, and (iii) the characteristically fast spectral acquisition rate of the time-of-flight (TOF) analyser renders the present arrangement an important contribution to future semipreparative fraction collection setups which use mass spectrometry as a detector. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1187 / 1190
页数:4
相关论文
共 5 条
[1]   PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY USING A THERMOSPRAY SOURCE IN THE FILAMENT-ON MODE [J].
BERRY, AJ ;
GAMES, DE ;
MYLCHREEST, IC ;
PERKINS, JR ;
PLEASANCE, S .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (02) :105-109
[2]   PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY/MASS SPECTROMETRY VIA A 2-STAGE MOMENTUM SEPARATOR [J].
EDLUND, PO ;
HENION, JD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (06) :274-282
[3]   ONLINE COMBINATION OF SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
MATSUURA, K ;
TAKEUCHI, M ;
NOJIMA, K ;
KOBAYASHI, T ;
SAITO, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) :381-383
[4]   Capillary column supercritical fluid chromatography-atmospheric pressure ionisation mass spectrometry -: Interface performance of atmospheric pressure chemical ionisation and electrospray ionisation [J].
Sjöberg, PJR ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :317-327
[5]   Analytical supercritical fluid chromatography using fully automated column and modifier selection valves for the rapid development of chiral separations [J].
Villeneuve, MS ;
Anderegg, RJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :217-225