A conformal transceive array for 7 T neuroimaging

被引:47
作者
Gilbert, Kyle M. [1 ]
Belliveau, Jean-Guy [1 ,2 ]
Curtis, Andrew T. [1 ,3 ]
Gati, Joseph S. [1 ]
Klassen, L. Martyn [1 ]
Menon, Ravi S. [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Biomed Engn, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5K8, Canada
基金
加拿大健康研究院;
关键词
transmit array; transceiver; radiofrequency coil; decoupling; parallel imaging; signal-to-noise ratio; TRANSMISSION-LINE ARRAY; HIGH-FIELD MRI; PHASED-ARRAY; SURFACE COIL; RADIOFREQUENCY COIL; PARALLEL TRANSMIT; STEADY-STATE; HUMAN BRAIN; HUMAN HEAD; TESLA;
D O I
10.1002/mrm.23124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The first 16-channel transceive surface-coil array that conforms to the human head and operates at 298 MHz (7 T) is described. Individual coil elements were decoupled using circumferential shields around each element that extended orthogonally from the former. This decoupling method allowed elements to be constructed with arbitrary shape, size, and location to create a three-dimensional array. Radiofrequency shimming achieved a transmit-field uniformity of 20% over the whole brain and 14% over a single axial slice. During radiofrequency transmission, coil elements couple tightly to the head and reduce the amount of power necessary to achieve a mean 90 degrees flip angle (660-mu s and 480-mu s pulse lengths were required for a 1-kW hard pulse when shimming over the whole brain and a single axial slice, respectively). During reception, the close proximity of coil elements to the head increases the signal-to-noise ratio in the periphery of the brain, most notably at the superior aspect of the head. The sensitivity profile of each element is localized beneath the respective shield. When combined with the achieved isolation between elements, this results in the capacity for low geometry factors during both transmit and receive: 1.04/1.06 (mean) and 1.25/1.54 (maximum) for 3-by-3 acceleration in the axial/sagittal plane. High cortical signal-to-noise ratio and parallel imaging performance make the conformal coil ideal for the study of high temporal and/or spatial cortical architecture and function. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1487 / 1496
页数:10
相关论文
共 45 条
[1]   Transmit and receive transmission line arrays for 7 tesla parallel imaging [J].
Adriany, G ;
Van de Moortele, PF ;
Wiesinger, F ;
Moeller, S ;
Strupp, JP ;
Andersen, P ;
Snyder, C ;
Zhang, XL ;
Chen, W ;
Pruessmann, KP ;
Boesiger, P ;
Vaughan, T ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :434-445
[2]   A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla [J].
Adriany, Gregor ;
De Moortele, Pierre-Francois Van ;
Ritter, Johannes ;
Moeller, Steen ;
Auerbach, Edward J. ;
Akguen, Can ;
Snyder, Carl J. ;
Vaughan, Thomas ;
Ugurbill, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :590-597
[3]   A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla [J].
Adriany, Gregor ;
Auerbach, Edward J. ;
Snyder, Carl J. ;
Gozubuyuk, Ark ;
Moeller, Steen ;
Ritter, Johannes ;
Van de Moortele, Pierre-Francois ;
Vaughan, Tommy ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) :1478-1485
[4]  
Alagappan V., 2006, PROC 14 SCI M ISMRM, P121
[5]  
[Anonymous], 2007, Proc Intl Soc Mag Reson Med
[6]   Improved Homogeneity of the Transmit Field by Simultaneous Transmission with Phased Array and Volume Coil [J].
Avdievich, Nikolai I. ;
Oh, Sukhoon ;
Hetherington, Hoby P. ;
Collins, Christopher M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (02) :476-481
[7]  
Barberi EA, 2000, MAGNET RESON MED, V43, P284, DOI 10.1002/(SICI)1522-2594(200002)43:2<284::AID-MRM16>3.0.CO
[8]  
2-C
[9]   Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz [J].
Collins, CM ;
Yang, QX ;
Wang, JH ;
Zhang, X ;
Liu, H ;
Michaeli, S ;
Zhu, XH ;
Adriany, G ;
Vaughan, JT ;
Anderson, P ;
Merkle, H ;
Ugurbil, K ;
Smith, MB ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1026-1028
[10]   A radiofrequency coil to facilitate B1+ shimming and parallel imaging acceleration in three dimensions at 7 T [J].
Gilbert, Kyle M. ;
Curtis, Andrew T. ;
Gati, Joseph S. ;
Klassen, L. Martyn ;
Menon, Ravi S. .
NMR IN BIOMEDICINE, 2011, 24 (07) :815-823