Acquired pulmonary vein stenosis after radiofrequency catheter ablation of paroxysmal atrial fibrillation

被引:149
作者
Yu, WC
Hsu, TL
Tai, CT
Tsai, CF
Hsieh, MH
Lin, WS
Lin, YK
Tsao, HM
Ding, YA
Chang, MS
Chen, SA
机构
[1] Taipei Vet Gen Hosp, Div Cardiol, Taipei, Taiwan
[2] Natl Yang Ming Univ, Dept Med, Div Cardiol, Taipei, Taiwan
关键词
atrial fibrillation; pulmonary vein stenosis; radiofrequency catheter ablation;
D O I
10.1046/j.1540-8167.2001.00887.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Elimination of the initiating focus within the pulmonary vein (PV) using radiofrequency (PF) catheter ablation is a new treatment modality for treatment of drug-refractory atrial fibrillation. However, information on the long-term safety of PF ablation within the PV is limited. Methods and Results: In 102 patients with drug-refractory atrial fibrillation and at least one initiating focus from the PV, series transesophageal echocardiography was performed to monitor the effect of RF ablation on the PV. There were 66 foci in the right upper PV and 65 foci in the left upper PV. Within 3 days of ablation, 26 of the ablated right upper PVs (39 %) had increased peak Doppler flow velocity (mean 130 +/- 28 cm/sec, range 106 to 220), and 15 of the ablated left upper PVs (23%) had increased peak Doppler flow velocity (mean 140 +/- 39 cm/sec, range 105 to 219). Seven patients had increased peak Doppler flow velocity in both upper PVs. No factor (including age, sex, site of ablation, number of RF pulses, pulse duration, and temperature) could predict PV stenosis after RF ablation. Three patients with stenosis of both upper PVs experienced mild dyspnea on exertion, but only one had mild increase of pulmonary pressure. There was no significant change of peak and mean flow velocity and of PV diameter in sequential follow-up studies up to 16 (209 +/- 94 days) months. Conclusion: Focal PV stenosis is observed frequently after PF catheter ablation applied within the vein, but usually is without clinical significance. However, ablation within multiple PVs might cause pulmonary hypertension and should be considered a limiting factor in this procedure.
引用
收藏
页码:887 / 892
页数:6
相关论文
共 27 条
[1]   DIAGNOSIS AND CURE OF THE WOLFF-PARKINSON-WHITE SYNDROME OR PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIAS DURING A SINGLE ELECTROPHYSIOLOGIC TEST [J].
CALKINS, H ;
SOUSA, J ;
ELATASSI, R ;
ROSENHECK, S ;
DEBUITLEIR, M ;
KOU, WH ;
KADISH, AH ;
LANGBERG, JJ ;
MORADY, F .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) :1612-1618
[2]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[3]   Editorial comment: Can we avoid pulmonary vein stenosis following ablation of atrial fibrillation? [J].
Chen, SA ;
Yu, WC ;
Tai, CT .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (04) :633-634
[4]   THE SURGICAL-TREATMENT OF ATRIAL-FIBRILLATION .2. INTRAOPERATIVE ELECTROPHYSIOLOGIC MAPPING AND DESCRIPTION OF THE ELECTROPHYSIOLOGIC BASIS OF ATRIAL-FLUTTER AND ATRIAL-FIBRILLATION [J].
COX, JL ;
CANAVAN, TE ;
SCHUESSLER, RB ;
CAIN, ME ;
LINDSAY, BD ;
STONE, C ;
SMITH, PK ;
CORR, PB ;
BOINEAU, JP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 101 (03) :406-426
[5]   ELECTRODE RADIUS PREDICTS LESION RADIUS DURING RADIOFREQUENCY ENERGY HEATING - VALIDATION OF A PROPOSED THERMODYNAMIC MODEL [J].
HAINES, DE ;
WATSON, DD ;
VEROW, AF .
CIRCULATION RESEARCH, 1990, 67 (01) :124-129
[6]   RADIOFREQUENCY CATHETER ABLATION OF LEFT LATERAL ACCESSORY PATHWAYS VIA THE CORONARY SINUS [J].
HAISSAGUERRE, M ;
GAITA, F ;
FISCHER, B ;
EGLOFF, P ;
LEMETAYER, P ;
WARIN, JF .
CIRCULATION, 1992, 86 (05) :1464-1468
[7]   Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Garrigue, S ;
Takahashi, A ;
Lavergne, T ;
Hocini, M ;
Peng, JT ;
Roudaut, R ;
Clementy, J .
CIRCULATION, 2000, 101 (12) :1409-1417
[8]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[9]   Double multielectrode mapping catheters facilitate radiofrequency catheter ablation of focal atrial fibrillation originating from pulmonary veins [J].
Hsieh, MH ;
Chen, SA ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Liu, CC ;
Ding, YA ;
Chang, MS .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (02) :136-144
[10]   SHORT-TERM AND LONG-TERM EFFECTS OF TRANSCATHETER ABLATION OF THE CORONARY SINUS BY RADIOFREQUENCY ENERGY [J].
HUANG, SKS ;
GRAHAM, AR ;
BHARATI, S ;
LEE, MA ;
GORMAN, G ;
LEV, M .
CIRCULATION, 1988, 78 (02) :416-427