Maximum likelihood estimation in calibrating a stereo camera setup

被引:7
作者
Muijtjens, AMM [1 ]
Roos, JMA [1 ]
Arts, T [1 ]
Hasman, A [1 ]
机构
[1] Univ Maastricht, Dept Med Informat, Cardiovasc Res Inst Maastricht, NL-6200 MD Maastricht, Netherlands
关键词
3-D reconstruction of marker positions; image processing; motion and deformation; myocardium; biomechanics;
D O I
10.1118/1.598518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Motion and deformation of the cardiac wall may be measured by following the positions of implanted radiopaque markers in three dimensions, using two x-ray cameras simultaneously. Regularly, calibration of the position measurement system is obtained by registration of the images of a calibration object, containing 10-20 radiopaque markers at known positions. Unfortunately, an accidental change of the position of a camera after calibration requires complete recalibration. Alternatively, redundant information in the measured image positions of stereo pairs can be used for calibration. Thus, a separate calibration procedure can be avoided. In the current study a model is developed that describes the geometry of the camera setup by five dimensionless parameters. Maximum Likelihood (ML) estimates of these parameters were obtained in an error analysis. It is shown that the ML estimates can be found by application of a nonlinear least squares procedure. Compared to the standard unweighted least squares procedure, the ML method resulted in more accurate estimates without noticeable bias. The accuracy of the ML method was investigated in relation to the object aperture. The reconstruction problem appeared well conditioned as long as the object aperture is larger than 0.1 rad. The angle between the two viewing directions appeared to be the parameter that was most likely to cause major inaccuracies in the reconstruction of the 3-D positions of the markers. Hence, attempts to improve the robustness of the method should primarily focus on reduction of the error in this parameter. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02502-X].
引用
收藏
页码:310 / 318
页数:9
相关论文
共 24 条
[1]  
Bard Y., 1974, Nonlinear Parameter Estimation
[2]   AN ALGORITHM FOR 3-D AUTOMATIC MOVEMENT DETECTION BY MEANS OF STANDARD TV CAMERAS [J].
BORGHESE, NA ;
FERRIGNO, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) :1221-1225
[3]   AN IMPROVED VIDEO-BASED COMPUTER TRACKING SYSTEM FOR SOFT BIOMATERIALS TESTING [J].
DOWNS, J ;
HALPERIN, HR ;
HUMPHREY, J ;
YIN, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (09) :903-907
[4]   PROPAGATION AND REDUCTION OF ERROR IN 3-DIMENSIONAL STRUCTURE DETERMINED FROM BIPLANE VIEWS OF UNKNOWN ORIENTATION [J].
FENCIL, LE ;
METZ, CE .
MEDICAL PHYSICS, 1990, 17 (06) :951-961
[5]   MEASUREMENT OF 3-DIMENSIONAL POSITIONS AND MOTIONS OF LARGE NUMBERS OF SPHERICAL RADIOPAQUE MARKERS FROM BIPLANE CINERADIOGRAMS [J].
GARRISON, JB ;
EBERT, WL ;
JENKINS, RE ;
YIONOULIS, SM ;
MALCOM, H ;
HEYLER, GA ;
SHOUKAS, AA ;
MAUGHAN, WL ;
SAGAWA, K .
COMPUTERS AND BIOMEDICAL RESEARCH, 1982, 15 (01) :76-96
[6]  
Hart P.E., 1973, Pattern recognition and scene analysis
[7]  
Horn B., 1986, Robot Vision
[8]  
HUNTER WC, 1989, INNOVATIONS DIAGNOST, P169
[9]   MEASUREMENT OF MIDWALL MYOCARDIAL DYNAMICS IN INTACT MAN BY RADIOGRAPHY OF SURGICALLY IMPLANTED MARKERS [J].
INGELS, NB ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL .
CIRCULATION, 1975, 52 (05) :859-867
[10]   ASSESSMENT OF REGIONAL MYOCARDIAL PERFORMANCE FROM BIPLANE CORONARY CINEANGIOGRAMS [J].
KONG, Y ;
MORRIS, JJ ;
MCINTOSH, HD .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (05) :529-&