Evaluation of a system using oral mucosal transudate for HIV-1 antibody screening and confirmatory testing

被引:127
作者
Gallo, D
George, JR
Fitchen, JH
Goldstein, AS
Hindahl, MS
机构
[1] EPITOPE INC,BEAVERTON,OR 97008
[2] CALIF DEPT HLTH SERV,VIRAL & RICKETTSIAL DIS LAB,BERKELEY,CA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 1997年 / 277卷 / 03期
关键词
D O I
10.1001/jama.277.3.254
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective.-To determine accuracy of a human immunodeficiency virus type 1 (HIV-1) antibody testing system using a device to collect and stabilize oral mucosal transudate (OMT), a fluid with increased levels of IgG; an enzyme immunoassay (EIA) screening test optimized for OMT; and a Western blot confirmatory test designed for use with OMT, Design.-The OMT specimens were tested by EIA and, if indicated, confirmatory Western blot according to a standard testing algorithm. The OMT results were compared with true HIV status as determined by serum testing and/or clinical diagnosis. Patients.-Specimens from 3570 subjects (2382 at low risk, 698 at high risk, 242 with acquired immunodeficiency syndrome [AIDS], and 248 ''nonspecificity'' [persons with diseases associated with an increased frequency of false-positive results in HIV testing]) were collected at If geographically diverse sites (including blood banks, public health clinics, general medical clinics, HIV clinics, sexually transmitted disease clinics, and a hemophilia center) in the United States. Main Outcome Measures.-Overall accuracy of testing OMT for HIV-1 antibodies compared with true HIV-1 antibody status; sensitivity and specificity of OMT EIA and Western blot, Results-Sensitivity of OMT EIA testing in 673 true-positive subjects was 99.9% (672/673). The OMT Western blot results in the 673 true-positive subjects were positive in 665 and indeterminate in 8. The EIA followed by Western blot (a EIA was repeatedly reactive) yielded a negative result in 99.9% (2893/2897) of OMT samples from true negatives and an indeterminate result in 4. The OMT testing system provided the correct result or would trigger appropriate follow-up testing in 3569 (>99.9%) of 3570 cases, Conclusion.-HIV-1 antibody testing of OMT samples is a highly accurate alternative to serum testing.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 33 条
[1]  
ARCHIBALD DW, 1986, BLOOD, V67, P831
[2]   THE INFLUENCE OF DENTAL STATUS ON THE DETECTION OF IGG CLASS ANTIVIRAL ANTIBODIES IN HUMAN SALIVA [J].
BAGG, J ;
PERRY, KR ;
PARRY, JV ;
MORTIMER, PP ;
PETERS, TJ .
ARCHIVES OF ORAL BIOLOGY, 1991, 36 (03) :221-226
[3]  
BEHETS FM, 1991, J ACQ IMMUN DEF SYND, V4, P183
[4]  
Brandtzaeg P, 1989, HUMAN SALIVA CLIN CH, VII, P1
[5]  
COATES R, 1991, CAN J PUBLIC HEALTH, V82, P397
[6]   REDUCTION OF MATERNAL-INFANT TRANSMISSION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 WITH ZIDOVUDINE TREATMENT [J].
CONNOR, EM ;
SPERLING, RS ;
GELBER, R ;
KISELEV, P ;
SCOTT, G ;
OSULLIVAN, MJ ;
VANDYKE, R ;
BEY, M ;
SHEARER, W ;
JACOBSON, RL ;
JIMENEZ, E ;
ONEILL, E ;
BAZIN, B ;
DELFRAISSY, JF ;
CULNANE, M ;
COOMBS, R ;
ELKINS, M ;
MOYE, J ;
STRATTON, P ;
BALSLEY, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (18) :1173-1180
[7]   A COMPARATIVE-STUDY OF SALIVA AND ORASURE(R) ORAL FLUID [J].
CORDEIRO, ML ;
TURPIN, CS ;
MCADAMS, SA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 694 :330-331
[8]   TESTING OF SALIVA FOR ANTIBODIES TO HIV-1 [J].
CROFTS, N ;
NICHOLSON, S ;
COGHLAN, P ;
GUST, ID .
AIDS, 1991, 5 (05) :561-563
[9]  
*CTR DIS CONTR, 1987, MMWR-MORBID MORTAL W, V36, P509
[10]  
*CTR DIS CONTR, 1992, MMWR-MORBID MORTAL W, V41, P613