Optimization of thoracic spiral CT: Effects of iodinated contrast medium concentration

被引:42
作者
Rubin, GD [1 ]
Lane, MJ [1 ]
Bloch, DA [1 ]
Leung, AN [1 ]
Stark, P [1 ]
机构
[1] STANFORD UNIV,SCH MED,DEPT BIOSTAT,STANFORD,CA 94305
关键词
arteries; CT; computed tomography (CT); artifact; contrast enhancement; veins;
D O I
10.1148/radiology.201.3.8939232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the effect of varying iodine concentration on arterial enhancement and perivenous artifact during thoracic spiral computed tomographic (CT) scanning. MATERIALS AND METHODS: One hundred thirty-eight outpatients received 15.0 g (n = 76) or 22.5 g (n = 62) of iodine (300 mg/mL iodine) while undergoing thoracic spiral CT. Patients received either undiluted contrast medium, 1:1 normal saline dilution, or 3:1 normal saline dilution. Contrast medium was injected at a flow rate determined to deliver the entire iodine dose within 40 seconds. Attenuation was measured within arteries and veins. Three blinded thoracic radiologists independently graded perivenous artifact and arterial enhancement. RESULTS: Perivenous artifacts were statistically significantly reduced with successive iodine dilution (P < .002). Arterial enhancement was statistically significantly better with 15.0 g of iodine diluted 1:1 when compared with the same iodine dose undiluted or diluted 3:1 (P < .01). Arterial enhancement achieved with 15.0 g of iodine diluted 1:1 was not statistically significantly lower than that achieved with 22.5 g of iodine diluted 1:1 (P > .31); however, venous artifact was greater with 22.5 g of iodine (P < .004). CONCLUSION: Reduced iodine concentration appears to diminish perivenous artifact and to result in improved arterial enhancement during thoracic spiral CT.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 10 条
[2]   CONTRAST-MEDIA TONICITY .1. EFFECTS UPON IV-DSA TIME CONCENTRATION CURVE PEAK AND WIDTH - EXPERIMENTAL STUDIES [J].
BURBANK, FH ;
THOMPSON, WM .
INVESTIGATIVE RADIOLOGY, 1986, 21 (03) :240-247
[3]   EFFECT OF VOLUME AND RATE OF CONTRAST-MEDIUM INJECTION ON INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHIC CONTRAST-MEDIUM CURVES [J].
BURBANK, FH ;
BRODY, WR ;
BRADLEY, BR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (02) :308-315
[4]   SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY [J].
COSTELLO, P ;
DUPUY, DE ;
ECKER, CP ;
TELLO, R .
RADIOLOGY, 1992, 183 (03) :663-666
[5]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[6]  
PALMER F J, 1988, Australasian Radiology, V32, P8, DOI 10.1111/j.1440-1673.1988.tb02684.x
[7]  
PROKOP M, 1993, RADIOLOGY, V189, P111
[8]   CENTRAL PULMONARY THROMBOEMBOLISM - DIAGNOSIS WITH SPIRAL VOLUMETRIC CT WITH THE SINGLE-BREATH-HOLD TECHNIQUE - COMPARISON WITH PULMONARY ANGIOGRAPHY [J].
REMYJARDIN, M ;
REMY, J ;
WATTINNE, L ;
GIRAUD, F .
RADIOLOGY, 1992, 185 (02) :381-387
[9]   AN EXPERIMENTAL EVALUATION OF CENTRAL VS PERIPHERAL INJECTION FOR INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY (IV-DSA) [J].
RUBIN, DL ;
BURBANK, FH ;
BRADLEY, BR ;
BRODY, WR .
INVESTIGATIVE RADIOLOGY, 1984, 19 (01) :30-35
[10]   SPIRAL CT OF THE MEDIASTINUM - OPTIMIZATION OF CONTRAST-MEDIUM USE [J].
STORTO, ML ;
CICCOTOSTO, C ;
PATEA, RL ;
SPINAZZI, A ;
BONOMO, L .
EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 :S83-S87