Interactive coronary MRI

被引:25
作者
Hardy, CJ
Darrow, RD
Pauly, JM
Kerr, AB
Dumoulin, CL
Hu, BS
Martin, KM
机构
[1] GE, Corp Res & Dev, Schenectady, NY 12301 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Div Cardiovasc Med, Stanford, CA 94305 USA
关键词
cardiac MRI; coronary imaging; interactive imaging; MRI;
D O I
10.1002/mrm.1910400115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The acquisition of complete three-dimensional (3D), segmented gradient-echo data sets to visualize the coronary arteries can be both time consuming and sensitive to motion, even with use of multiple breath-holding or respiratory gating, An alternate hybrid approach is demonstrated here, in which real-time interactive imaging is first used to locate an optimal oblique coronary scan plane. Then, a limited number of contiguous slices are acquired around that plane within a breath-hold with use of two-dimensional (2D) segmented gradient-echo imaging. Dual inversion nulling is used to suppress fat and myocardium. Finally, if needed, a limited reformat of the data is performed to produce images from relatively long sections of the coronaries. This approach yields relatively rapid visualization of portions of the coronary tree. Several different methods are compared for interactively moving the scan plane.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 27 条
[1]  
[Anonymous], 1996, VISUALIZATION TOOLKI
[2]   Cardiac magnetic resonance fluoroscopy [J].
Debbins, JP ;
Riederer, SJ ;
Rossman, PJ ;
Grimm, RC ;
Felmlee, JP ;
Breen, JF ;
Ehman, RL .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :588-595
[3]   2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS [J].
DUERINCKX, AJ ;
URMAN, MK .
RADIOLOGY, 1994, 193 (03) :731-738
[4]   A METHOD OF CORONARY MR ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD ;
ADAMS, WJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :705-710
[5]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[6]   REAL-TIME ACQUISITION, DISPLAY, AND INTERACTIVE GRAPHIC CONTROL OF NMR CARDIAC PROFILES AND IMAGES [J].
HARDY, CJ ;
DARROW, RD ;
NIETERS, EJ ;
ROEMER, PB ;
WATKINS, RD ;
ADAMS, WJ ;
HATTES, NR ;
MAIER, JK .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :667-673
[7]   A ONE-DIMENSIONAL VELOCITY TECHNIQUE FOR NMR MEASUREMENT OF AORTIC DISTENSIBILITY [J].
HARDY, CJ ;
BOLSTER, BD ;
MCVEIGH, ER ;
ADAMS, WJ ;
ZERHOUNI, EA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :513-520
[8]  
HARDY CJ, 1996, P ISMRM 4 ANN M NEW, P1496
[9]  
HARDY CJ, 1994, P SMR 2 ANN M SAN FR, P500
[10]  
HARDY CJ, 1997, P ISMRM 5 ANN M VANC, P440